user login

24 Meter Position Single Phase Electrical Energy Meter Test Equipment High Accuracy

Place of Origin: Zhejiang

Company Profile

Location: Guangzhou, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Energy Meter Test Bench

Product Detail

Model No.: KE8102

Product Description

24 Meter Position Single Phase Electrical Energy Meter Test Equipment High Accuracy

 

  1. Usage: Auto Electric meter test and calibration
  2. Accuracy Class:  0.05%
  3. Phase: Single Phase
  4. Meter position: 12 / 24 / 48 / 60 position
  5. Name: Energy meter test equipment, electric meter test bench
  6. Power: Electronic
  7. Voltage Output: 24V – 300V
  8. Current Output:  1mA – 120A
  9. Operating Temperature: -10°C -- +40°C
  10. Supporting the auto test of two current sample meters

 

Single Phase Electric Meter Test Equipment With 24 Meter Position

 

This system is used for the test of various single phase electric and mechanical meter, multi-function meter, PLC meter, multi-rate meter and prepayment meter.

 

Highlight:

  • Integrated/separated aluminum alloy structure, light and reliable, flexible choices
  • Meter positions can be chosen from 12-60
  • Perfect alarming protective function, auto protection of the short circuit of voltage, the open circuit of current, and overload.
  • Double current channel, supporting the auto test of two current sample meters
  • The open circuit test of neutral voltage (optional)
  • Auto mark locking increases the efficiency of test
  • Supporting bar code input, which increase the efficiency of input
  • Full automatic, semi automatic and manual operation available
  • Simultaneous test of the energy meters with same specification, different constants and different classes.
  • Adopt multi-serial port system, realizing the parallel communication of computer and the tested meters (optional)
  • Forward and reverse active energy/ forward and reverse reactive energy error test
  • Creeping and starting test
  • Standard deviation, 24 hour variation test
  • Influencing quantity test of voltage, frequency, harmonic
  • Calibration and verification of constant
  • Register indicating value, register combination error test
  • Powerful computer management system, easy and user-friendly
  • Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms

 

Main Specification:

 

 

KE8102-12

KE8102-24

KE8102-48

KE8102-60

Number of meter position

12

24

48

60

Accuracy

±0.05%

Voltage output

Output range (P-N)

24V – 300V

Output power of voltage

250VA

500VA

1000VA

1500VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%