Place of Origin: | Zhejiang |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Mini Circuit Breaker, Molded Case Circuit Breakers, Residual Current Circuit Breaker |
Model No.: | BW-A1D |
---|
Detailed Description:
Name:BW-B2D
Voltage:AC125V,250V
Current:10Amax
Dimension:18.5*8.0*4.2 20*8.0*4.2
L1=L2=70mm or customized according to customers'requirement
Applications:AC Motors
Product Introduction:
BW-B2D Plastic Thermal Overload Protector With TUV, UL ,VDE , CQC is consist of high sensitive bimetal , active contact-head , passive contact plate , outer case , thermal resistant lead etc .
When operating , bimetal disc is in free state , active contact head and passive contact plate are closed and circuit is on . When working electric machine is in operation and produce heat caused by some trouble and temperature raise to the rated action temp. . The bimetal produce inner stress and act quickly to push the movable contact head and make the contact point off . In the end ,power supply is cut down. Overheat protection is completed .
When the machine attached temperature decrease to rated reset temperature , bimetal restore to initial state that the movable contact head close , the machine continue working .
Competitive Advantage :
Small resistance , quick sensitive to temperature , action quickly , reliable , small in size
Attention :
The thermal protector hereof applies to electrical and mechanical , ballast , and other types of electrical , electronic equipment and household appliances and parts , overheat protection , to prevent dangerous overheat components under fault conditions , in order to avoid accidents .
Sealed structure , which ensure it to work consistently under severe conditions . When the outer case is metal , when circuit is on ,this metal case is electrified body , when installation , please apply the insulated jacket from our factory .
When you select the specific thermal protector , remember to choose the one which meets the specification which suits the working voltage and circuit .
When installation , pay attention that lead connection in good condition prevent it from virtual connection which will cause extra heat to influene the normal working of protector .
General Temperature specification
Action Temp. |
Reset Temp. |
Action Temp. |
Reset Temp. |
Action Temp. |
Reset Temp. |
Action Temp. |
Reset Temp. |
45±5 |
≥27 |
80±5 |
53±15 |
115±5 |
76±15 |
150±5 |
100±15 |
50±5 |
≥30 |
85±5 |
56±15 |
120±5 |
80±15 |
155±5 |
103±15 |
55±5 |
≥30 |
90±5 |
60±15 |
125±5 |
83±15 |
160±5 |
106±15 |
60±5 |
40±15 |
95±5 |
63±15 |
130±5 |
86±15 |
165±5 |
110±15 |
65±5 |
43±15 |
100±5 |
67±15 |
135±5 |
90±15 |
170±5 |
113±15 |
70±5 |
46±15 |
105±5 |
70±15 |
140±5 |
93±15 |