user login

High capacity three phase low frequency 100Kva ups online for industry use

2399.0~39999.0 USD
Min. Order: 2 Piece/Pieces
Trade Term: EXW
Payment Terms: L/C, T/T, WU
Supply Ability: 1500 piece per month
Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Online UPS, High Frequency UPS, Low Frequency UPS

Product Detail

Model No.: PV33100II
Means of Transport: Ocean, Air, Land
Application: Security / Monitoring / Alarm
Phase: Three Phase
Type: On-line
Protection: Short Circuit
Brand Name: HRD
Weight: 230-2700kg
Output Voltage: 190/208/220/380/400/415Vac
Product name: low frequency 100Kva ups
Output PF: 0.8
Input PF: 0.99
Input frequency: 50/60 auto-sense
Event log: 1000 items
System efficiency: 94% reachable
MTBF: >200,000h
MMTM: <0.5h
Warranty: 2 years
Certification: CE
Production Capacity: 1500 piece per month
Packing: Standard wooden packing with pallet
Delivery Date: 4 weeks after payment confirmed
Show

Product Description

High capacity three phase low frequency 100Kva ups online for industry use

 

1.Application for the low frequency 100Kva ups:


Middle and large data center,telecom,finance,traffic,defense,medical,education,energy,manufacture, industry,etc.


2.Features for the low frequency 100Kva ups:


1.Adopting full DSP control with high speed CPU 32bit, high reliable design, world-leading driver protection and VCE protection.Ensuring ups with high stability(MTBF>200,000h) and excellent performance;

2.The 6th generation IGBT inverter technology, UPS efficiency reaching 90-95%;

3.World-leading UPS parallel technology,  low cycle current, high stable and easy connection;

    A.Common battery bank, save battery cost for parallel,

    B.Different capacity can be parrallel and load share divided by ups capacity ratio.

4.Advanced battery management: 

   A.Peridic battery self test,

   B.Default 0.1C charging current, best for battery lifespan,

   C.Recharge termperature compensation(optional).

5. Remaining backup time display;

    By using powerful algorithm,an estimated remaining back up time can be calculated and displayed on the     LCD screen, 

    which can help users to make a further arrangement when AC power goes off. 

6.Event log up to 1000 items;

   Classified events, easy to check and helpful for fast maintenance 

7.Frequency convertor mode function input 50Hz output 60Hz or reverse;

8.Full frontal access of all components, convenient for maintenance;

9.From bottom and to top air flow, so it can be installed against of the wall to save space;

10.Ups stream protection for installation engineer and system's safety;

11.Abundant communication interface, RS232,RS485,dry contact,SNMP card(optional);

12.Colorful 7 inch touch screen, with high resolution, friendly human-machine interface;

13.Intelligent self-diagnosis, if ups failed,engineer can find out the problem in short time.

 

 3.Specification for the low frequency 100Kva ups:

Model

PV3310II

PV3315II

PV3320II

PV3330II

PV3340II

PV3360II

PV3380II

PV33100II

PV33120II

Capacity

10KVA

15KVA

20KVA

30KVA

40KVA

60KVA

80KVA

100KVA

120KVA

System

Output PF 

0.9 (lag)

System efficiency  (inverter mode)

92%(@100% load) ;90% @50%load;

System efficiency  (ECO mode)

98%(@100%load)

Maximum leakage current

100(mA)

MTBF

Above 200,000hours

Dry contact

 Standard: 3 types signal(BAT. low,battery mode,bypass /failure);

Optional:14 dry contact ; output: 12Vdc 80mA

Communication interface

Standard RS232,optional: RS485 / MODBUS

Operation temperature

0 ~ 40 °C

Humidity

95 % (non-condense)

Cooling

Forced air(speed varying according to load percent)

Max. altitude

Within 1000m(every 100increase,capacity decrease -1%),Maximum 4000m

Noise (dB)

52 ~ 58

IP protection

(EN 60529)

IP20

Input/output way

Bottom /rear

Safety standard

safety:GB4943 ,EN 50091-1;EMI:GB7260.2,GB/T 17626.2~5EMC, EN 50091-2

Physical

W *D*H(mm)

600*600*1280

800*800*1480

800*800*1800

Weight(Kg)

230

250

260

305

345

500

560

610

710

AC input

Rated voltage

 380/400/415VAC  Three-phase three-wire

Input voltage range

± 15 %- ± 25 % adjustable)

Rate frequency

50 / 60 Hz  auto-sense

Frequency range

50/60Hz+/-5Hz

Input soft start function

0 - 100%,10-300s(settable)

Input power factor

Reachable 0.99(plus harmonic filter)

Input current harmonic component(THDi )

Can<5%(plus harmonic filter)

Max. input current [A]

18

27

36

54

72

108

144

180

216

The output characteristic of the rectifier

Maintain the voltage (20°C)

Battery type1 and 2 :V =435Vdc (2.266 x el.)

Battery type 3 :V =424Vdc (2.21 x el.)

 Battery type 0:the voltage value between type 1and 2,

Voltage regulating range: V =400~460Vdc

Charging voltage (20°C)

Battery type1 and 2 :V (%recharging<95%) = 445Vdc (2.32 x el.)

Battery type 3 :V (%recharging<95%) = 460Vdc (2.4 x el.)

Battery type 0: the voltage value between type 1and 2,

Voltage regulating range: V =400~460Vdc

The highest charging voltage

445V

The charger output voltage regulation accuracy

1%

DC ripple voltage component

≤1%

Battery

Unit number(rated voltage)

384VDC(360-384v,selectable)

Charging current settings

0.1C(battery capacity)

The battery discharge end voltage

Battery type 1,2 and 3:no-load discharge current,V min=346 [V dc]

Battery type 1,2 and 3:output current =Ah capacity,V min=316 [V dc]

Battery type 1,2 and 3:output current >Ah capacity,V min=306 [V dc]

Battery type 0: the factory set the default values,V min=320 [V dc]  

Regulating range: V min =300~360[V dc]

Inverter output

Rated capacity  [KVA]

10

15

20

30

40

60

80

100

120

Rated power  [KW]

9

13.5

18

27

36

54

72

90

108

Rated voltage  [V]

 380/400/415VAC  three-phase four-wire

Rated current  [A]

12

18

24

36

48

72

96

120

144

Phase voltage setting

200 ~ 244 V (control board)

Peak factor

3:1

Waveform

Sine wave

Voltage phase shift (degrees)       100% balanced load

± 1'

Voltage phase shift (degrees)

100% unbalanced load

± 2'

Phase voltage difference         100% balance load

± 1 %

Phase voltage difference         100% unbalanced load

± 3 %

Total harmonic content(THD v)                                100% linear load

<2%

Total harmonic content(THD v)                               100% non-linear load

<5%

Steady-state voltage stability

± 1 %

Transient voltage response

± 5 % within 10ms

Rated frequency

Same as input

Frequency stability

When asynchronous,± 0.5 %;synchronization,± 2 %

(can be set to ± 1~5 %,by the panel operation)

Overload

  600' / 10' / 1' (110/125/150% rated current)

Short circuit 0.1s

Double input

Inverter efficiency           (load 100%)

98%

Bypass

Rated capacity  [KVA]

10

15

20

30

40

60

80

100

120

Rated voltage  [V]

 380/400/415VAC Three-phase four-wire

Input voltage range

±15 %(can be adjusted from the control panel ± 10 %,± 20%)

Rated frequency       [Hz]

50 / 60

Frequency range

±2 %(can be adjusted from the control panel ± 5 %)

"STAND-BY ON"(Eco mode, the bypass switch to inverter)transfer time

2~5ms

Inverter/bypass transfer time

<1ms

Overload

10'/1'/18" (150/175/200% Rated current)

Standard configuration

Feed flow protection, bypass independently isolated



















 

4.About us:

Shenzhen HRD Science & Technology Co., Ltd. is a large high professional UPS manufacturer,with ISO 9001:2008

and ISO 14001:2004 certified. Based on the most advanced and the stalest technique guarantee system, HRD

provides the following products and custom made product  for global customer.


1)UPS power supply ( uninterrupted power supply)600va-600Kva 

2)Inverter(electricity,solar etc.system)1-200Kva

3)EPS(emergency power supply)10-200Kva 

4)Lead-acid maintenance-free battery 


With the same diligent customer-oriented spirit, HRD is dedicated to continuously designing, manufacturing,

marketing and introducing a complete line of UPS, inverters and power products to the demanding power market.


With 2 large  manufacture  base and strict quality traceable syste, HRD makes sure to deliver high quality goods

on time for our global customer.


So far, our good quality power product are exporting to more than 60 countries all over the world, stragety partners

including world-famous UPS brand.


We sincerely and warmly welcome you to visit us and cooperate with us! 

 

 

5.Our service:

A. Reply your inquiry within 24 hours.

B. Experienced staff answer all your questions in fluent English.

C. Customized design is available.OEM&ODM are welcomed.

D. Exclusive and unique solution can be provided to our customer by our well-trained and professional engineers  and staff.

E. Special discount and protection of sales area provided to our distributor.

 

6.FAQ:


1. What is uninterrupted power supply?

An UPS, uninterruptible power supply,  is an electrical apparatus that provides emergency power to a load,when the AC power is on,

it can have the function of filter and AVR, providing high quality power source. 


2.What is the difference between high frequency UPS and low frequency UPS?

Item

High   frequency UPS

Low   frequency UPS

Input PF

0.99

0.7

Efficiency

85-90%

75-85%

Power density

Higher

Lower

Power device capacity

Less

More

Weight

Light

Heavy

Dimension

Compact

Bigger

Price

Lower

Higher

Overload ability

Normal

Better

Anti input sugar capacity

Normal

Better

Output anti-crush , short circuit capacity

Normal

Better

N-G voltage

Bad

Better

Output component

More

Less

Damage extent of device when it's fail

Higher

Lower

Stability

Normal

Better

Compatibility with   generator

Bad

Better



We are ready for your kind enquiry and offering  you with top high end quality product in best price! 


Contact person: Doris Du 

Skype: Doris.du620     QQ:1428867260

Email: Doris at hrdups.com    dorisdu620 at hrdups.com  

Mobile: 0086-15220221361


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



Post Buying Request