Min. Order: | 2 Piece/Pieces |
---|---|
Trade Term: | EXW |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 1500 piece per month |
Place of Origin: | Guangdong |
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Online UPS, High Frequency UPS, Low Frequency UPS |
Model No.: | PVII Series 10-600Kva |
---|---|
Means of Transport: | Ocean, Air, Land |
Application: | Security / Monitoring / Alarm |
Phase: | Three Phase |
Type: | On-line |
Protection: | Short Circuit |
Brand Name: | HRD |
Weight: | 230-2700kg |
Output Voltage: | 190/208/220/380/400/415Vac |
Product name: | industrial ups power supply |
Output PF: | 0.8 |
Input PF: | 0.99 |
Input frequency: | 50/60 auto-sense |
Event log: | 1000 items |
System efficiency: | 94% reachable |
MTBF: | >200,000h |
MMTM: | <0.5h |
Warranty: | 2 years |
Certification: | CE |
Production Capacity: | 1500 piece per month |
Packing: | Standard wooden packing with pallet |
Delivery Date: | 4 weeks after payment confirmed |
10-600Kva high capacity online low frequency industrial ups power supply from China
1.Application for the industrial ups power supply:
Middle and large data center,telecom,finance,traffic,defense,medical,education,energy,manufacture, industry,etc.
2.Features for the industrial ups power supply:
1.Adopting full DSP control with high speed CPU 32bit, high reliable design, world-leading driver protection and VCE protection.
Ensuring ups with high stability(MTBF>200,000h) and excellent performance;
2.The 6th generation IGBT inverter technology, UPS efficiency reaching 90-95%;
3.World-leading UPS parallel technology, low cycle current, high stable and easy connection;
A.Common battery bank, save battery cost for parallel,
B.Different capacity can be parrallel and load share divided by ups capacity ratio.
4.Advanced battery management:
A.Peridic battery self test,
B.Default 0.1C charging current, best for battery lifespan,
C.Recharge termperature compensation(optional).
5. Remaining backup time display;
By using powerful algorithm,an estimated remaining back up time can be calculated and displayed on the LCD screen,
which can help users to make a further arrangement when AC power goes off.
6.Event log up to 1000 items;
Classified events, easy to check and helpful for fast maintenance
7.Frequency convertor mode function input 50Hz output 60Hz or reverse;
8.Full frontal access of all components, convenient for maintenance;
9.From bottom and to top air flow, so it can be installed against of the wall to save space;
10.Ups stream protection for installation engineer and system's safety;
11.Abundant communication interface, RS232,RS485,dry contact,SNMP card(optional);
12.Colorful 7 inch touch screen, with high resolution, friendly human-machine interface;
13.Intelligent self-diagnosis, if ups failed,engineer can find out the problem in short time.
3.Specification for the industrial ups power supply:
Model | PV3310II | PV3315II | PV3320II | PV3330II | PV3340II | PV3360II | PV3380II | PV33100II | PV33120II | ||||||||
Capacity | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | ||||||||
System | |||||||||||||||||
Output PF | 0.9 (lag) | ||||||||||||||||
System efficiency (inverter mode) | 92%(@100% load) ;90% @50%load; | ||||||||||||||||
System efficiency (ECO mode) | 98%(@100%load) | ||||||||||||||||
Maximum leakage current | 100(mA) | ||||||||||||||||
MTBF | Above 200,000hours | ||||||||||||||||
Dry contact | Standard: 3 types signal(BAT. low,battery mode,bypass /failure); Optional:14 dry contact ; output: 12Vdc 80mA | ||||||||||||||||
Communication interface | Standard RS232,optional: RS485 / MODBUS | ||||||||||||||||
Operation temperature | 0 ~ 40 °C | ||||||||||||||||
Humidity | 95 % (non-condense) | ||||||||||||||||
Cooling | Forced air(speed varying according to load percent) | ||||||||||||||||
Max. altitude | Within 1000m(every 100increase,capacity decrease -1%),Maximum 4000m | ||||||||||||||||
Noise (dB) | 52 ~ 58 | ||||||||||||||||
IP protection (EN 60529) | IP20 | ||||||||||||||||
Input/output way | Bottom /rear | ||||||||||||||||
Safety standard | safety:GB4943 ,EN 50091-1;EMI:GB7260.2,GB/T 17626.2~5EMC, EN 50091-2 | ||||||||||||||||
Physical | |||||||||||||||||
W *D*H(mm) | 600*600*1280 | 800*800*1480 | 800*800*1800 | ||||||||||||||
Weight(Kg) | 230 | 250 | 260 | 305 | 345 | 500 | 560 | 610 | 710 | ||||||||
AC input | |||||||||||||||||
Rated voltage | 380/400/415VAC Three-phase three-wire | ||||||||||||||||
Input voltage range | ± 15 %- ± 25 % adjustable) | ||||||||||||||||
Rate frequency | 50 / 60 Hz auto-sense | ||||||||||||||||
Frequency range | 50/60Hz+/-5Hz | ||||||||||||||||
Input soft start function | 0 - 100%,10-300s(settable) | ||||||||||||||||
Input power factor | Reachable 0.99(plus harmonic filter) | ||||||||||||||||
Input current harmonic component(THDi ) | Can <5%(plus harmonic filter) | ||||||||||||||||
Max. input current [A] | 18 | 27 | 36 | 54 | 72 | 108 | 144 | 180 | 216 | ||||||||
The output characteristic of the rectifier | |||||||||||||||||
Maintain the voltage (20°C) | Battery type1 and 2 :V =435Vdc (2.266 x el.) | ||||||||||||||||
Battery type 3 :V =424Vdc (2.21 x el.) | |||||||||||||||||
Battery type 0:the voltage value between type 1and 2, Voltage regulating range: V =400~460Vdc | |||||||||||||||||
Charging voltage (20°C) | Battery type1 and 2 :V (%recharging<95%) = 445Vdc (2.32 x el.) | ||||||||||||||||
Battery type 3 :V (%recharging<95%) = 460Vdc (2.4 x el.) | |||||||||||||||||
Battery type 0: the voltage value between type 1and 2, Voltage regulating range: V =400~460Vdc | |||||||||||||||||
The highest charging voltage | 445V | ||||||||||||||||
The charger output voltage regulation accuracy | 1% | ||||||||||||||||
DC ripple voltage component | ≤1% | ||||||||||||||||
Battery | |||||||||||||||||
Unit number(rated voltage) | 384VDC(360-384v,selectable) | ||||||||||||||||
Charging current settings | 0.1C(battery capacity) | ||||||||||||||||
The battery discharge end voltage | Battery type 1,2 and 3:no-load discharge current,V min=346 [V dc] | ||||||||||||||||
Battery type 1,2 and 3:output current =Ah capacity,V min=316 [V dc] | |||||||||||||||||
Battery type 1,2 and 3:output current >Ah capacity,V min=306 [V dc] | |||||||||||||||||
Battery type 0: the factory set the default values,V min=320 [V dc] Regulating range: V min =300~360[V dc] | |||||||||||||||||
Inverter output | |||||||||||||||||
Rated capacity [KVA] | 10 | 15 | 20 | 30 | 40 | 60 | 80 | 100 | 120 | ||||||||
Rated power [KW] | 9 | 13.5 | 18 | 27 | 36 | 54 | 72 | 90 | 108 | ||||||||
Rated voltage [V] | 380/400/415VAC three-phase four-wire | ||||||||||||||||
Rated current [A] | 12 | 18 | 24 | 36 | 48 | 72 | 96 | 120 | 144 | ||||||||
Phase voltage setting | 200 ~ 244 V (control board) | ||||||||||||||||
Peak factor | 3:1 | ||||||||||||||||
Waveform | Sine wave | ||||||||||||||||
Voltage phase shift (degrees) 100% balanced load | ± 1' | ||||||||||||||||
Voltage phase shift (degrees) 100% unbalanced load | ± 2' | ||||||||||||||||
Phase voltage difference 100% balance load | ± 1 % | ||||||||||||||||
Phase voltage difference 100% unbalanced load | ± 3 % | ||||||||||||||||
Total harmonic content(THD v) 100% linear load | <2% | ||||||||||||||||
Total harmonic content(THD v) 100% non-linear load | <5% | ||||||||||||||||
Steady-state voltage stability | ± 1 % | ||||||||||||||||
Transient voltage response | ± 5 % within 10ms | ||||||||||||||||
Rated frequency | Same as input | ||||||||||||||||
Frequency stability | When asynchronous,± 0.5 %;synchronization,± 2 % (can be set to ± 1~5 %,by the panel operation) | ||||||||||||||||
Overload | 600' / 10' / 1' (110/125/150% rated current) | ||||||||||||||||
Short circuit 0.1s | Double input | ||||||||||||||||
Inverter efficiency (load 100%) | 98% | ||||||||||||||||
Bypass | |||||||||||||||||
Rated capacity [KVA] | 10 | 15 | 20 | 30 | 40 | 60 | 80 | 100 | 120 | ||||||||
Rated voltage [V] | 380/400/415VAC Three-phase four-wire | ||||||||||||||||
Input voltage range | ±15 %(can be adjusted from the control panel ± 10 %,± 20%) | ||||||||||||||||
Rated frequency [Hz] | 50 / 60 | ||||||||||||||||
Frequency range | ±2 %(can be adjusted from the control panel ± 5 %) | ||||||||||||||||
"STAND-BY ON"(Eco mode, the bypass switch to inverter)transfer time | 2~5ms | ||||||||||||||||
Inverter/bypass transfer time | <1ms | ||||||||||||||||
Overload | 10'/1'/18" (150/175/200% Rated current) | ||||||||||||||||
Standard configuration | Feed flow protection, bypass independently isolated | ||||||||||||||||
4.About us:
Shenzhen HRD Science & Technology Co., Ltd. is a large high professional UPS manufacturer,with ISO 9001:2008
and ISO 14001:2004 certified. Based on the most advanced and the stalest technique guarantee system, HRD
provides the following products and custom made product for global customer.
1)UPS power supply ( uninterrupted power supply)600va-600Kva
2)Inverter(electricity,solar etc.system)1-200Kva
3)EPS(emergency power supply)10-200Kva
4)Lead-acid maintenance-free battery
With the same diligent customer-oriented spirit, HRD is dedicated to continuously designing, manufacturing,
marketing and introducing a complete line of UPS, inverters and power products to the demanding power market.
With 2 large manufacture base and strict quality traceable syste, HRD makes sure to deliver high quality goods
on time for our global customer.
So far, our good quality power product are exporting to more than 60 countries all over the world, stragety partners
including world-famous UPS brand.
We sincerely and warmly welcome you to visit us and cooperate with us!
5.Our service:
A. Reply your inquiry within 24 hours.
B. Experienced staff answer all your questions in fluent English.
C. Customized design is available.OEM&ODM are welcomed.
D. Exclusive and unique solution can be provided to our customer by our well-trained and professional engineers and staff.
E. Special discount and protection of sales area provided to our distributor.
6.FAQ:
1. What is uninterrupted power supply?
An UPS, uninterruptible power supply, is an electrical apparatus that provides emergency power to a load,when the AC power is on,
it can have the function of filter and AVR, providing high quality power source.
2.What is the difference between high frequency UPS and low frequency UPS?
Item | High frequency UPS | Low frequency UPS |
Input PF | 0.99 | 0.7 |
Efficiency | 85-90% | 75-85% |
Power density | Higher | Lower |
Power device capacity | Less | More |
Weight | Light | Heavy |
Dimension | Compact | Bigger |
Price | Lower | Higher |
Overload ability | Normal | Better |
Anti input sugar capacity | Normal | Better |
Output anti-crush , short circuit capacity | Normal | Better |
N-G voltage | Bad | Better |
Output component | More | Less |
Damage extent of device when it's fail | Higher | Lower |
Stability | Normal | Better |
Compatibility with generator | Bad | Better |