Min. Order: | 1000 Piece/Pieces |
---|---|
Payment Terms: | L/C, D/P, D/A, T/T |
Supply Ability: | 2000pcs/day |
Place of Origin: | Guangdong |
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Power Adapter, AC DC Adapter |
Model No.: | UT60 |
---|---|
Means of Transport: | Ocean, Air, Land |
Output Type: | DC |
Usage: | Switching |
Connection: | Desktop |
Brand Name: | uniontop |
Output: | 18V 3.5A |
Color: | black |
Warranty: | 1 year |
Usage: | switching |
Output type: | DC |
Test: | EMC standard |
Protection: | Short, over voltage,over current |
Packing: | polybag&carton box |
Connection: | Desktop |
MOQ: | 1000PCS |
Production Capacity: | 2000pcs/day |
Packing: | PE bag+white box+carton box |
Delivery Date: | 25 working days |
Features:
1.1 Input:
1.1.1 Input Range Voltage 100-240Vac Full voltage 90-264Vac
1.1.2 Input Range Frequency 50Hz(min)-60Hz(max)
1.1.3 Efficiency 80%min. At full load and within input voltage 230Vac
1.2 Input Protection:
1.2.1 Over-current Input power is off by a fuse Fuse ratings 3.15A/250Vac
1.3 Output:
1.3.1 Output Voltage: +18V±5%, +32V±5%
1.3.2 Output Current: 0.2A 0.05A, 2.5A 1.5A
1.3.3 Line Regulation 1% max.
1.3.4 Load Regulation 5% max. Min load to Max load
1.3.5 Output Power 51.6W MAX At full load and within input voltage 120-240Vac
1.3.6 Ripple + Noise: 180mV max. 320mV max. Oscilloscope bandwidth=20MHz, 10uF/50V electrolytic and 0.1uF/50V ceramic capacitors are connected at output.
1.3.7 Rise Time 2S max. At Vin=230Vac/60Hz
1.3.8 OCP +32V 3.0~3.3A INPUT:115VAC OUTPUT:+18V/0.2A, +32V/1.5A
1.4 Output Protection:
1.4.1 Over-load No odor, smoke, fire, plastic deformation, and excessive heat happen.
Increase load current gradually until the output is shorted or burst.
1.4.2 Short-circuit No odor, smoke, fire, plastic deformation, and excessive heat happen.
Over the operating temperature range.
2. Environmental Characteristics:
2.1 Storage Temperature Range: -20°C to +60°C
2.2 Operating Temperature Range: 0°Cto +40°C
2.3 Storage RH Range: 5 to 95% RH: Relative Humidity
2.4 Operating RH Range 20 to 90%
2.5 Burn-in 4 hours (The new model forfirst production for 4 hour; Mass production for 2 hours)
Each unit before shipping, full load at Vin=220Vac
Ordering Information | |||
Model | O/P Voltage(V) | O/P Current(A) | Watt(W) |
UT60-XXXYYY-ZZ | 5-8.0V | 0-6Amax | 44W max |
UT60-XXXYYY-ZZ | 8.1-13.5V | 0-5Amax | 60W max |
UT60-XXXYYY-ZZ | 13.6-18V | 0-4.96Amax | 60W max |
UT60-XXXYYY-ZZ | 18.1-24V | 0-4Amax | 65W max |