CT Analyzer Current Transformer Analyzer

1.0~8.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: L/C, T/T, WU
Supply Ability: 100pcs/month
Place of Origin: Chongqing

Company Profile

Location: Chongqing, China (Mainland)
Business Type: Manufacturer
Main Products: Oil Purifier, Oil Testing Equipment, Electrical Testing Set

Product Detail

Model No.: GDVA-405
Means of Transport: Ocean, Air, Land
Usage: Universal Testing Machine
Power: Electronic
Brand Name: Gold
Function: CT PT Analyzer
Test Standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
Power supply: AC220V±10%,50Hz/60Hz±10%
Warranty: 1 Year
Production Capacity: 100pcs/month
Packing: Wooden Case
Delivery Date: 10 business days
Show

Product Description

Product model: GDVA-405 CT PT Analyzer

 

ISO CERTIFICATION  

 

Tests for Current Transformer:

1 Excitation curve and parameters test
2 Turns ratio test
3 Ratio and phase error test
4 Polarity mark check
5 Winding resistance measurement
6 Secondary loop burden measurement
7 Error line curve test for protection CT
8 Transient CT parameters test
9 CT nameplate guess
10 Saturation hysteresis loop curve measurement

Tests for Voltage Transformer:

1 Turns ratio test
2 Ratio error and phase angle error test
3 Polarity test
4 Secondary burden test
5 Winding resistance test

Applications of CT/PT Analyzer:

1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis
4 CT ratio and phase error calibration
5 PT routine test

CT PT Analyzer Function and Technical Index:

1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2 Power supply: AC220V±10%, 50/60Hz±10%
3 Voltage output: 0.1~180V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output: 500VA
6 Maximum knee voltage measurement: 45KV
7 Current measurement:
  Range: 0~10A (automatically change range in 0.1/0.4/2/10A) 
  Error: <±0.1%+0.01%FS
8 Voltage measurement:
  Range: 0~200V (automatically change range in 1V/10V/70V/200V)
  Error: < ±0.1%+0.01%FS
9 Turns ratio measurement:
  Range:1~35000
  1~2000     error<0.05%
  2000~5000  error<0.1%
  5000~35000  error<0.2%
10 Phase measurement: error: ±2min; resolution: 0.01min
11 Winding resistance measurement: 
   Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
   Error: < 0.2%RDG+0.02%FS
   Maximum resolution: 0.1mΩ
12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree
13 CT Secondary burden:
   Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
   Error: <0.2%RDG+0.02%FS 
   Maximum resolution: 0.001ohm
14 PT Secondary burden:
   Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
   Error :<0.2%RDG+0.02%FS 
   Maximum resolution: 0.1ohm
15 PT ratio measurement:
   Range: 1~35000
   1~10000 error<0.1%
   10000~35000 error<0.2%
16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
17 PT phase angle measurement: maximum error < 3min
18 Make evaluation for test results according to selected standards
19 Make word report for test result
20 Make word reports one time for multi-group test records on the PC
21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
22 Compare excitation curves with saved excitation curves in the same window
23 Memory capacity: >1000 groups test results 
24 Working condition: temperature: -10℃~50℃; moist: ≤90%

 


Post Buying Request