Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 100pcs/month |
Place of Origin: | Chongqing |
Location: | Chongqing, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Oil Purifier, Oil Testing Equipment, Electrical Testing Set |
Model No.: | GDGS |
---|---|
Means of Transport: | Ocean, Air, Land |
Brand Name: | Gold |
Weight: | 40KG |
Warranty: | 1 Year |
Production Capacity: | 100pcs/month |
Packing: | Wooden Case |
Delivery Date: | 10 business days |
1 Power Factor Tester application
GDGS automatic tangent delta tester is applied to measure the dielectric loss and capacitor value of insulation materials in high voltage power equipment. The non-power frequency voltage source is integrated in the tester to avoid power frequency interference. That make the tester has a good performance in measurement precision.
2 Power Factor Tester technique index
1 Measurement error:
Capacitor value: 1%RDG+5pf
Tangent delta: 1%RDG+0.04%
2 Output voltage:AC 0.5kV~10KV
3 Testing voltage setting resolution: 0.5kv
4 Maximum output capacity: 200mA
5 Testing frequency: 45Hz/55Hz
6 Test mode: fully automatic
7 Power supply: AC220V±10 % 50Hz/60Hz
8 Environment temperature: 0~50°C
9 Humidity: ≤85%RH
10 Weight:40KG