Place of Origin: | Zhejiang |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | AC DC Power Adapter, Wall Mount Power Adapter, Switching Power Adapters |
Model No.: | W&T-LEDOP12W-A |
---|
T8 T9 T10 LED Tube Driver Open Frame Power Supply 12V / 24V LED Thin Power Module
Quick Detail:
Input/Output Specifications:
Input voltage: 100V-240V AC, 50/60Hz
Range voltage: 86V-265V AC, 47-63Hz
Output power: 6~12W
Output voltage: DC 12.0V ~ 52.0V
Continuous current range: 200MA~1.0A
Safety:
PSE UL CE GS EK FCC CB BS CCC
Competitive Advantage:
High efficiency power(Level VI)
Meets "ENERGY STAR" program requirement
Over voltage protection
Over load & short circuit protection
100% full load burn-in test
Application in LED products
Application:
It’s apply to T8/ T9 / T10 all plastic and plastic composite tubes and widely used in the factory, hospital, garage, school, family, public places ect LED light driver
Datasheet spec:
OUTPUT |
PART NO. |
W&T-LEDOP12WXXX |
Voltage |
DC 12V ~ 52V |
|
Current Range |
0 ~ 1.0A |
|
Output Tolerance |
±5% |
|
Ripple Noise(MAX) |
150 mV |
|
Efficiency(MIN) |
≥80% |
|
Rated Power |
0 -12W |
|
INPUT |
Voltage |
86-265VAC universal full range |
Frequency |
47-63Hz |
|
Inrush Current |
40A@115V , 60A@230V AC input.Cold start at 25 ambient |
|
PROTECTION |
Over Voltage |
Over 120%-140% |
Shutdown and latch off, recover after re-start up |
||
Over Current & Short Circuit |
Above 105%-110% rated output power or short circuit acted,powr supply will be shutdown and recover automatically after the fault is removed |
|
Over Temperature |
Over 95,the power supply will shutdown. |
|
ENIRONMENT |
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min. each along X,Y,Z axes |
Temperature |
Operating:-2070;De-rating:4570:2.5%/;Storage:-40+85 |
|
Humidity |
Operating: 20%90% RH(non condensing);Storage:10%95% RH(non condensing) |
|
SAFETY |
Withstand voltage |
I/P-O/P:3KVAC,I/P-PE:1.5KVAC,O/P-PE:0.5KVAC,1 minute |
Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG>100MΩ/500VDC at 25/70% RH |
|
Safety standard |
UL 60950-1 2nd,CSA C22.2 No.60950-1-07 2nd,TU EN 60950-1:2006, UL1310 Class 2. IEC 60950-1:25005,standard,EN61347-1,EN61347-2,EN61347-13 |
|
EMC |
EMI |
EN 55015,EN 55022 CLASS B,FCC CFR 47 PART 15 CLASS B,CNS 13438 CLASS B |
Compliance to EN61000-3-2 CLASS D,EN61000-3-3 |
||
EMS |
EN61547,EN55024:EN61000-4-2,3,4,5,6,8,11;EN55024,lightindustry level, criteria A |
|
OTHERS |
M.T.B.F. |
100K hours |
Dimension |
17.5 x 18 x 10mm ( L*W*H ) |
|
Packing |
N.W.:0.05kg/1pc; 15pcs/0.75kg CUFT/1 CTN |
Mechanical spec
Factory View: