12V 1.25A 15W Industrial Switching Power Supply For GSM Alarm System Adapter
Quick Detail:
Input Voltage:100V~240V AC 50/60HZ
Input Voltage Range:90V~265V AC
Input Frequency Range:47~63Hz
Output Voltage Range: DC 5.0V ~ 24V
Output Current Range: 0 ~ 3.0A
Dimension: 60*39*31MM (L*W*H)
Environment:
Working Temp:-20 ~ +70
Working Humidity:20 ~ 90%RH non-condensing
Storage Temp, Humidity:-40 ~ +85,10 ~ 95%RH
Temp. Coefficient:±0.03%/(0 ~ 50)
Safety & EMC:
Compliance to UL60950-1,EN60950-1
Compliance to EN55022(CISPR22) Class B
Compliance to EN61000-3-2,-3
CE FCC CB
Application:
ADXX/Advertising machine power adapter
• shelter camera adapter
• LED street lamp power adapter
• Network router power adapter
• phone program-controlled device
• Medical power supply
• wave soldering equipment power supply
• Telecom equipments power supply
• GSM alarm system adapter
• intercom system adapter
Data sheet Spec:
INPUT | Voltage | 90-264VAC universal full range | Frequency | 47-63Hz | Current | 0.5A@100V AC input, full load condition | Inrush Current | 40A@115V , 60A@230V AC input.Cold start at 25 ambient | Leakage Current | 0.5A@ 264V AC input | OUTPUT | PART NO. | GYD-15W-05 | GYD-15W-12 | GYD-15W-24 | Voltage | 5V | 12V | 24V | Max Load | 0-2.5A | 0-1.25A | 0-0.625A | Output Tolerance | ±5% | ±5% | ±5% | Ripple Noise(MAX) | 50mV | 120mV | 200mV | Efficiency(MIN) | ≥75% | ≥85% | ≥85% | Output MAX | 15W | 15W | 15W | PROTECTION | Over Voltage | over 120%150 max | Shutdown and latch off, recover after re-start up | Over Load & Short Circuit | When power supply over 105%150 max load or short circuit acted,powr supply will be shutdown and recover automatically after the fault is removed | Over Temperature | Over 95,the power supply will shutdown. | ENIRONMENT | Temperature | Operating:-2070;De-rating:4570:2.5%/;Storage:-40+85 | Humidity | Operating: 20%90% RH(non condensing);Storage:10%95% RH(non condensing) | SAFETY | Withstand voltage | I/P-O/P:3KVAC,I/P-PE:1.5KVAC,O/P-PE:0.5KVAC,1 minute | Isolation resistance | I/P-O/P,I/P-FG,O/P-FG>100MΩ/500VDC at 25/70% RH | Safety standard | UL 60950-1 2nd,CSA C22.2 No.60950-1-07 2nd,TU EN 60950-1:2006, IEC 60950-1:25005,standard | EMC | EMI | EN 55022 CLASS B,FCC CFR 47 PART 15 CLASS B,CNS 13438 CLASS B | Compliance to EN61000-3-2 CLASS D,EN61000-3-3 | EMS | EN55024:EN61000-4-2,3,4,5,6,8,11 | OTHERS | Cooling | Natural Cooling | M.T.B.F. | 100K hours | Dimension | 70x39x31mm ( L*W*H ) | Packing | N.W.:70g/1pc; 15pcs/1.05kg CUFT/1 CTN |
|