Features and Uses: This capacitor is used in the tram road link of ZPW-2000A electric locomotive to offset and widen the communication signal, then convey the signal to the locomotive operating room and platform commander, to assure its performance safety.
Rated voltage: 160VAC
Standard capacitance:40 µF 46µF 50µF 60µF 70µF (testing frequency)
Capacitance allowable:±5% Losstangent:tgδ≤70x10-4 (testing frequency:1000HZ)
Insulation resistance between leading-out:>500MΩ IOOVAC 1 min
Withstand voltage testing: 100Vac 50HZ 10S
Climate intensity:No stronger than 95% in 30℃
Reliable working life:no less than 5 years(practical use)
标称容量µF |
450VAC |
D |
H |
40 |
60 |
135 |
46 |
50 |
55 |
155 |
60 |
70 |
65 |
165 |
80 |
90 |