Place of Origin: | Zhejiang |
---|
Location: | Nanjing, Jiangsu, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Mold Temperature Controller, Industrial Temperature Controller, Injection Mold Temperature Controller |
Model No.: | ACH-50W(A) |
---|
Microcomputer Temperature Control Units Black For Plastic Injection Molding
Quick details
Rapid Heat&Cool Temperature Control Unit
Switchover of heating power
Control mode : imported microcomputer or PLC
used in injection machine, injection molding process
ACH series Rapid Heat&Cool Temperature Control Unit with signal injection machine, injection molding process in accordance with system requirements of the output hot water or cold water(cooling water) to ensure the injection mold, when in touch all the good flow of plastic to eliminate air bubbles
Applications:
ACH series Rapid Heat&Cool Temperature Control Unit are mailnly used in injection machine, injection molding process and so on.
Competitive Advantage:
1. Compressor head imported from Europe and USA
2. Oxygen-free welding for copper pipes
3. RS485 communication function for automatedmanagement (optional)
4. Switchover of heating power
5. 304 stainless steel integrated pipelines for less pipe resistance and rust
6. Imported quality parts for longer service lives
7. Brands OMRON , FUJI , TE , LG , MOELLER , ABB and WEST for electric appliances
8. Control mode : imported microcomputer or PLC (optional)
9. Perfect safety protection , fault display , easy repair and maintenance even without professionals
10. High-efficiency evaporator and condenser which can save energy by more than 30%
11. Two groups of compressor heads (used separately or jointly) for C-20
12. Temperature control range: Inlet water temperature +5ºC→98ºC; Range of low/high temperature control : -15ºC→150ºC.
Specifications:
Model |
Unit |
ACH-50W(A) |
|
Refrigerating capacity |
Kcal/h |
132.359 |
|
KW |
153.91 |
||
Power supply |
3N-380V/415V 50HZ/60HZ |
||
Compressor |
Type |
Totally closed vortex type or piston type |
|
Power |
KW |
7.5*5 |
|
Cooling water |
Quantity of water |
M³/h |
33.09 |
Water resistance |
Kpa |
42 |
|
Diameters of inlet and outflow tube |
G3’’ |
||
Chilled Water |
Quantity of water |
M³/h |
26.48 |
Water resistance |
M³ |
0.61 |
|
Diameters of inlet and outflow tube |
G3’’ |
||
Cold Water Pump |
Power |
KW |
4 |
Lift |
KPA |
|