user login

23x10MM 12V Active Buzzer Alarm Piezo Transducer 3500500 Hz

Place of Origin: Zhejiang

Company Profile

Location: Changzhou, Jiangsu, China (Mainland)
Business Type: Manufacturer
Main Products: Electronic Buzzer, Piezo Electric Buzzer, Electro Magnetic Buzzer

Product Detail

Model No.: BPC2310-1235

Product Description

23x10MM 12V Active Buzzer Alarm Piezo Transducer 3500±500 Hz

 

Quick Detail:

  1. Size: D23mm*H10mm
  2. SPL: Min.95dB at 3.5KHz/12VDC 1/2 Duty Square Wave/10cm
  3. Operating Voltage: 6-15VDC

Description:

  1. buzzer
  2. Piezo Buzzer with build-in oscillating
  3. Piezo Buzzer
  4. 12V Buzzer
  5. 23mm Piezo Buzzer

 

Specification:

1.Technical Parameter

Measuring condition

Measuring condition

Part shall be measured under a condition (Temperature: 535, Humidity: 45%85%R.H., Atmospheric pressure: 860 1060hPa) unless the standard condition (Temperature: 25±3, Humidity: 60±10%R.H. Atmospheric pressure: 860 1060hPa) is regulated to measure.

1

Rated Voltage

12 VDC

2

Operating Voltage

6 – 15VDC

3

Rated Current

Max.15mA, at 12VDC

4

Sound Output at 10cm

Min.95dB, at 12VDC

5

Resonant Frequency

3500±500 Hz

6

Tone

Continuous

7

Operating Temperature

-20 - +70

8

Storage Temperature

-30 - +80

9

RoHS

Yes

10

Weight

Approx 3g

 
 
2. Dimensions   Unit: mm           Tolerance: ±0.5mm Except Specified
 
 

*Housing Material: Black ABS

3. Reliability Test

After any following tests the part shall meet specifications without any degradation in

appearance and performance except SPL. SPL shall not deviate more than -10 dB

from the initial value

(1)Ordinary Temperature Life Test

The part shall be subjected to 96 hours at 25±10. Input rated voltage

Resonant frequency, 1/2 duty Square wave.

(2)High Temperature Test

The part shall be capable of with standing a storage temperature of +80 for 96 hours.

(3)Low Temperature Test

The part shall be capable of with standing a storage temperature of ­-30 for 96 hours.

(4)Humidity Test

Temperature:+40±3   Relative Humidity:90%95% Duration: 48 hours

and expose to room temperature for 6 hours

(5)Temperature Shock Test

Temperature:70 /1hour→ 25/3hours→-30/1hour→ 25/3hours (1cycle)

Total cycle: 10 cycles

(6)Drop Test

Standard Packaging From 75mm(Drop on hard wood or board of 5cm thick,

three sides, six plain.)

(7)Vibration Test

Vibration:1000cycles /min. Amplitude:1.5mm, Duration: 1 hour in each 3 axes

Note:

As this product is not protected from foreign material entering, please make sure that any foreign materials (e.g. magnetic powder, washing solvent, flux, corrosive gas) do not enter this product in your production processes. The functional degradation (e.g. SPL down) may occur if foreign material enter it

4.Electrical And Acoustical Measuring Condition

 

Recommended Setting

    

You Might Also Like

Post Buying Request