Min. Order: | 1 Set/Sets |
---|---|
Payment Terms: | L/C, T/T, paypal, WU |
Supply Ability: | 2000pcs/month |
Place of Origin: | Guangdong |
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Main Products: | Electrical Safety Tester |
Model No.: | AUTO-SP |
---|---|
Means of Transport: | Ocean, Air, Land |
Usage: | Others |
Power: | Electronic |
Brand Name: | Autostrong |
Standard: | IEC60112 IEC60335 IEC60598 |
Control: | Touch screen control |
Power Supply: | 800VA ,220V, 48-60Hz |
Electrode Material:: | the electrode caput of brass and Platinum |
Test Process: | Automatic control,Independent ventilation |
Outer Size of Product: | W1100mm X D700mm X H1300mm |
Packing: | Wooden Case |
Warranty period: | One year |
After Service: | Professional Engineer Team |
OEM Service: | Can accept OEM order |
Production Capacity: | 2000pcs/month |
Packing: | wooden case |
Delivery Date: | 5-10days |
Longterm Supply High Quality UL94 Horizontal Vertical Flame Chamber :
1.Ref. standard:UL94,IEC60695-11-3,IEC60695-11-20
2.With CE,Rohs
SGS&ISO certificates
1.Introduction:
When there is a fire around the products, should ensure that it will not to cause the spread of the fire, horizontal-vertical burning test simulates electronic products around the environment in the early condition, using the simulation technology to assess the fire risk. The test equipment apply to the electrical and electronic product components of household appliances, spare parts and components, such as: household appliances insulation shell, Panel switches, printed circuit boards and insulation materials and so on.
horizontal vertical flame chamber is composed by the test part and control part, using the integrated design, to facilitate the installation at the scene and debug. The shell of the test chamber and the important parts are all manufactured by stainless steel, resistant cigarettes and gas corrosion. The automatic degree of control system is high. Has automatic ignition, the products which were tested in both vertical and horizontal orientation has the function automatically follow flame in the cross of the test. Time and temperature figures show, so that the observation and records is facilitate and the use of it is stable and reliable.
2.Technical parameters:
Kinds | 500W(5V class ) | 50W(HB/Vclass) |
Test Flame | 500W(burning test for V-0,V-1,V-2 classification) | 50W(burning test for V-0,V-1,V-2 classification) |
Burner Tube | Internal diameter: Φ 9.5mm±0.3mm | Internal diameter: Φ 9.5mm±0.3mm, |
Burning Angle | 0°,20°,45° | 0°,20°,45 ° |
Thermocouple | Type K (Ni/Cr - Ni/Al) | Type K (Ni/Cr - Ni/Al) |
Thermocouple Size | 0.5 mm | 0.5 mm |
Standard Copper Block | Φ9mm±0.01mm, weight:10g±0.05g before drilling. | Φ5.5mm±0.01mm, weight.76g±0.01g before drilling. |
Time for Temperature to Increase | From 100°C±5°C to 700°C±3°C; 54s±2s (preset) | From 100°C±5°C to 700°C±3°C; 44s±2s (preset) |
Gas Flow | 965±32ml/min | 105±10ml/min |
Gas Supply | methane,min.98% purity | methane,min.98% purity |
water-column | 125m±5mm | ‹10mm |
Test Time | 54±2s | 44±2s |
Flame Height Indicator | 40±1mm | 20±1mm |
Volume Of Chamber | >0.5m³, black interior | >0.5m³, black interior |
Conform to standard | UL94,IEC60695-11-3,IEC60695-11-20 | UL94,IEC60695-11-4,IEC60695-11-10 |