Min. Order: | 1 Set/Sets |
---|---|
Payment Terms: | L/C, T/T, paypal, WU |
Supply Ability: | 2000pcs/month |
Place of Origin: | Guangdong |
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Main Products: | Electrical Safety Tester |
Model No.: | AUTO-LD |
---|---|
Means of Transport: | Ocean, Air, Land |
Usage: | Others |
Power: | Electronic |
Brand Name: | Autostrong |
Standard: | IEC60112 IEC60335 IEC60598 |
Control: | Touch screen control |
Power Supply: | 800VA ,220V, 48-60Hz |
Electrode Material:: | the electrode caput of brass and Platinum |
Test Process: | Automatic control,Independent ventilation |
Outer Size of Product: | W1100mm X D700mm X H1300mm |
Packing: | Wooden Case |
Warranty period: | One year |
After Service: | Professional Engineer Team |
OEM Service: | Can accept OEM order |
Production Capacity: | 2000pcs/month |
Packing: | wooden case |
Delivery Date: | 5-10days |
Flammability Matesrial Lab Test Equipment IEC60112 Tracking Tester:
1.Manufacturer & Low price
2.Can be OEM
3.Reference standard:IEC60112 IEC60335-1 IEC60598-1
1.Introduction:
Tracking Tester is a fully automatic instrument contained in its own cabinet to maximize the safety of the operator. Inside the well lit cabinet, a test specimen is placed on a glass plate and two platinum electrodes are lowered onto the top surface.
A gauge block is supplied with the instrument to ensure the electrodes have the proper distance between them. The table height is easily adjustable to ensure the proper angle of the electrodes and height of drops. The rest of the test is controlled from outside the test chamber with the door closed.
The voltage,limiting current, drip rate and number of drips are all set on the control panel. An operator should observe the test to see if a flame ignites. The instrument sounds an alarm if there is a tracking failure of at least two seconds.
2.Features:
Self contained cabinet with large viewing window and internal light
Easy access to testing area during setup
Built in exhaust fan
Control panel has all controls in easy reach including lighting and exhaust
Platinum Electrodes 99.5% minimum purity
Alarm sounds if tracking failure occurs for more than 2 seconds
Safety interlock on door halts test if the door is opened
Easy adjustment to tes table height
3.Technical parameters:
Electrode Materials | The electrode caput of brass and platinum |
Electrode Distance | 4.0mm±0.1mm,60±5°angle |
Test Voltage | 100~600V adjustable, displayed value: r.m.s |
Test Current
| Current limiting 1A±0.1A adjustable, |
displayed value:r.m.s, tolerance of 1.5% | |
Electrode Dimensions
| width: 5mm±0.1mm, |
thickness: 2mm±0.1mm, | |
length >12mm, | |
end chisel-edge angle : 30°±2°,platinum. | |
Electrode Pressure | 1.00N±0.05N |
Dripping Nozzle | outer diameter: 0.9mm~1.2mm for solution A |
0.9mm~3.45mm for solution B | |
Dripping Interval | 0-99 seconds (adjustable),the time for 44-55/1cm3(adjustable) drops to fall on the specimen shall be (30±2)min. |
Heigh Drops | 30-40mm±5mm(adjustable) |
4.More details: