Min. Order: | 1 Set/Sets |
---|---|
Payment Terms: | L/C, T/T, paypal, WU |
Place of Origin: | Guangdong |
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Main Products: | Electrical Safety Tester |
Model No.: | AUTO-ZRS |
---|---|
Means of Transport: | Ocean, Air, Land |
Usage: | Others |
Power: | Electronic |
Brand Name: | Autostrong |
Standard: | IEC60695-2-10 ,UL746A ,IEC60335, IEC60598 |
Control: | Touch screen control |
Power Supply: | 800VA ,220V, 48-60Hz |
Thermocouple: | 0.5mm Type K (Ni/Cr-Ni/Al) |
Test Process: | Automatic control,Independent ventilation |
Outer Size of Product: | W1100mm X D700mm X H1300mm |
Packing: | Wooden Case |
Warranty period: | One year |
After Service: | Professional Engineer Team |
OEM Service: | Can accept OEM order |
Material Flammability Tester IEC60695 Glow Wire Tester
1.Ref standard: IEC60695-2-10&UL746A
2.WIth CE,ROHs,SGS,ISO certificate
1.Introduction:
The Glow Wire Test Device is designed to carry out fire hazard testing on electrotechnical products in accordance with the provisions of International standards- EC60695-2-10 ,UL746A ,IEC60335 and IEC60598 so on.
A digital temperature indicator is fitted which, in conjunction with the thermocouple supplied, accurately measures the glow wire temperature. The electrical circuit of the control unit is fully protected by fuses and a miniature circuit breaker and incorporates mains on/off switching and push button control of the output current. Self contained cabinet with large viewing window and dark colored interior
The control unit is supplied with all the controls and metering necessary to accurately set the temperature of the glow wire. The wire current is continuously variable by means of the panel-mounted controller and is monitored by the built-in ammeter.
2. Technical parameters:
Glow Wire | Ø 4mm±0.04mmNi/Cr(80/20), standard | |
Temperature Range | 500 ~ 1000 °C± 2 °C continuous adjustable | |
Thermocouple | Ø0.5mm Type K (Ni/Cr - Ni/Al), armored sheath can withstand temperature-40°C~ 1100°C | |
Searing Time | 30s±0.1s (OMRON H5CN-XAN-Z digital timer, 0-9999s, presettable) | |
Light-off Time | 0-999.9 s ± 0.1 s, automatic recording, manual timeout | |
Fireouttime | 0-999.9 s ± 0.1 s, automatic recording, manual timeout | |
Ironing into depth | 7mm ± 0.5 mm | |
Sample pressure | 1N ± 0.2 N | |
Test speed | 18±3mm/s | |
Test background | black background | |
Test process | automatic control, independent convulsions | |
Chamber | ≥0.5m | |
Size | W1100mm×D700mm×H1300mm, exhaust hole Ø100mm | |
Control | Using single chip microcomputer + touch screen control | |
Consult standard | GB/T5169.10-2006 , IEC60695-2-10:2000,UL746A | |
Power Supply | 800VA ,220V, 48-60Hz |
3.More Pictures: