user login

ClassI/I+II Surge Protector for LV Power Supply System

Place of Origin: Guangdong

Company Profile

Location: Foshan, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Surge Protective Device, SPD, TVSS.Surge Arrester

Product Detail

Model No.: G25P/320(-S)/PN100
Application: Industrial
Grounding: Others
Type: Electrical Plug
Brand Name: PROSURGE
Rated Voltage: 320
Rated Current: 50kA
T1/T1+2 surge protective device: class B+C SURGE PROTECTOR
Show

Product Description


HIT, Prosurge made type 1 & 2 coordinated surge arrester for low-voltage power supply system protection against surges 

at the boundaries from lightning protection zone 0B -2 and higher.

Ø Encapsulated spark gap technology to guarantee reliability in rugged environment

Ø 36mm pluggable design, easy maintenance 

Ø Comply with IEC61643-11 standard

Ø Discharge capacity Iimp 25kA 10/350 L-N, 100kA 10/350 N-PE

Ø Low voltage protection level 

Ø With remote signaling contact and failure indicator optional 

Type

G25P/xxx(-S)/3PN100

150

175

275

320

In accordance with

IEC61643-11:2011; UL1449 3rd

Category IEC/VDE

I+ II / B+C

Max. continuous operating voltage (V)

L – N

(AC/DC)

150

/200

175

/225

275

/350

320

/420

N–PE (AC)

150

150

255

255

Nominal discharge current(8/20) In

L–N

25kA

N-PE

100kA

Max. discharge current(8/20) Imax

L-N

100kA

N-PE

200kA

Lightning impulse current (10/350) Iimp

L-N

25kA

N-PE

100kA

Voltage protection level

L-N(1.2/50)

<1.2kV

<1.2kV

<1.2kV

<1.5kV

N–PE(1.2/50)

<0.8kV

<0.8kV

<1.5kV

<1.5kV

Response time

L-N

≤100 ns

N-PE

≤100 ns

short-circuit current rating (Isccr)& follow current interrupt rating (Ifi)

L-N

Isccr =10kArms ;  Ifi≥10kArms@255Vac

N-PE

Ifi =100Arms @ 255Vac

Backup fuse(only required if not already provided in mains)

250A gL/gG

Operating temperature range

- 40ºC ~ + 80ºC

Cross-section of connection wire

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

8 modules, DIN 43880

Thermal disconnector

Internal  green – normal ; red - failure

Remote alarm contact

Optional

Approvals, Certifications

CE

Additional data for Remote Alarm Contacts

Remote alarm contact type

floating changeover contact

Switching capability UN/IN

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Cross-section of connection wire

Max. 1.5mm2

 

 

Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Max. Size of connecting wire

Max. 1.5mm2(or # 16AWG)

 Please write to info@spd-china.com for more information.

 


Post Buying Request