Place of Origin: | Zhejiang |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Electrical Power Transformers, AC Power Transformers, Oil Immersed Power Transformer |
Model No.: | S11SZ11 ,S10SZ10, S9SZ9 |
---|
35KV 2MVA Power Supply Transformer , 50HZ Step Up And Step Down Transformer
Quick Detail:
1. Rated Voltage: 35kv
2. Rated Capacity: 2000kva
3. Phase: Three Phase
4. Cooling Type: ONAN
5. Frequency: 50Hz
Description:
The transformer is based upon world-wide advanced technology and also incorporates the experiences of internationally leading transformer companies as well as our own long-term experiences. Low loss, low partial discharge and high short circuit withstand capability series transformers are achieved through innovation and optimization. Our transformer conform entirely with latest national standard GB1094.1~2-1996, GB1094.3-2003, GB1094.5-2003 and international standard IEC-76.
Outstanding features as follows:
1. A multilayer cylinder structure is used for all high voltage windings in order to improve the voltage impulse distribution of windings.
2. For the capacity range of low voltage windings is from 30kVA to 2000kVA,the cylinder type or spiral structure is used to ensure the high mechanical strength, ampere lure distribution, and excellent short-circuits proof performance.
3. The securing structure is set in the transformer body, which is used for ensuring that no displacement will occur during the transportation; meanwhile, the turnbuckles are mounted in fasteners, which is for assuring that fasteners will not be loose during the long term operation.
4. Corrugated tanks are used in transformer for replacing the conservator. The tank enclosure and rim are completely sealed by welding or bolting up, which prolongs the service life of transformer oil.
5. The transformer surface are painted with primer and finish coats after derusting, and phosphorizing; which can meet the special operation requirements in metallurgic and petrochemical industries, as well as, in moist and dirty places.
6. The press relief valves, signal thermometers, and gas relays are equipped in the oil tank of hermetically sealed transformer in order to the standard requirements for safe operation. The transformers are attractive and competitive due to the compact shape, excellent design, and maintenance-free.
Technical Parameter Specifications:
Rated Voltage | 35kv |
Rated Capacity | 2000kva |
Cooling Type | ONAN |
Winding Type | Three winding |
Phase | Three phase |
Type | Core Type |
Winding Material | Copper |
Frequency | 50HZ |
Type |
Voltage (kV) |
Connection Symbol |
No-load Loss (KW) |
Load Loss (KW) |
No-load current |
Short-circuit Impedance (%) |
Weight (t) |
(mm) |
|||||
Body |
Oil |
Total |
Transport |
L |
W |
H |
|||||||
S9-800/35 |
35 |
±5% |
1.25 |
9.90 |
1.2 |
6.5 |
970 |
|