Min. Order: | 2000 Meter |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 200km/day |
Place of Origin: | Guangdong |
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Main Products: | Lan Cable , Fiber Cable , Network Cabinet &rack |
Means of Transport: | Ocean, Air, Land |
---|---|
Application: | Networking |
Type: | Others |
Brand Name: | TESO |
Number of Conductors: | 8cores |
Operating Temperature: | -20°C - +75°C (-4°F - +167°F) |
Application: | Networking |
Conductor: | Bare Copper |
Certification: | UL,CE ,ROHS |
Jacket: | PVC, LSZH, CMR,CMP |
Type: | SSTP |
Product Name: | Ethernet Lan Cable |
Insulation: | HDPE |
AWG: | 23AWG |
Rate: | 500MHZ |
item: | cat6a |
Production Capacity: | 200km/day |
Packing: | 305m/Box |
Delivery Date: | 15-20days |
Quick Detail:
1 High Quality 4pair Cat56a SSTP Lan Cable,500MHz ,23awg.
2.Structure: Bare copper conductor +HDPE insulation+ AL-Foil +Drain wire(customized)+ Braided shield + Jacket
3. Conductor: 1/0.575mm Bare copper , soft annealed bare copper.
4.Insulation: America Dow's HDPE
5.Outer jacket: PVC,LSZH,CMR,CMP are available and any color will be optional.
6.Test :Pass fluke test and with 25 years quality warranty.
Application
TESO Category 6A SSTP cables exceed TIA/EIA-568-B.2-10 Category 6A and ISO/IEC 11801:2002 Class EAperformance requirements by significant margins on all parameters.
The TESO Category 6A System complies with all of the performance requirements for current and proposed applications such as 10 Gigabit Ethernet, Gigabit Ethernet (1000BASE-Tx), 10/100BASE-Tx, token ring, 155 Mbps ATM, 100 Mbps TPPMD, ISDN, analog and digital video and analog and digital voice (VoIP).
Specification
Conductor bare copper AWG 23/1, massive
Insulation HDPE, ca. 1.37 mm outer Ø
Core identification code acc. to IEC 708-1
Pair screening plastic laminated aluminium foil
Pair 4 pairs
Screening braid of copper wire, tinned wire 0,10 mm
Outer sheath PVC, LSZH PVC ,CMR, outer Ø: ca. 7.4 mm
Electrical properties at 20° C
Resistance (loop) max. 150 Ω/km, acc. to VDE 0812
Insulation resistance min. 5 GΩxkm
Mutual capacitance nom. 45 nF/km
Characteristic impedance 100 Ω ±5 Ω
(at 100 MHz)
Velocity of propagation ca. 0.79 c
Signal propagation time <425 ns/100m
Delay difference <5 ns/100m
Screening attenuation >75 dB
(up to 600 MHz)
Test voltage 700 V (AC)
Cat6a SSTP shielded Twisted Pair Cable, Bulk cable Transmission properties
f [MHz] | Attenuation nom. [dB/100m] | NEXT nom. [dB] | ACR nom. [dB/100m] | ELFEXT nom. [dB/100m] | RL nom. [dB] |
1 | 1.8 | 105 | 103 | 95 | 25 |
4 | 3.3 | 105 | 103 | 93 | 28 |
10 | 5.3 | 105 | 100 | 92 | 30 |
16 | 6.7 | 105 | 98 | 91 | 32 |
20 | 7.5 | 105 | 97 | 90 | 34 |
31,25 | 9.6 | 105 | 95 | 86 | 35 |
62,5 | 13.8 | 103 | 89 | 82 | 34 |
100 | 17.3 | 100 | 83 | 77 | 33 |
155 | 22.6 | 98 | 75 | 73 | 30 |
200 | 24.8 | 95 | 70 | 70 | 29 |
300 | 30.7 | 93 | 62 | 67 | 27 |
400 | 35.8 | 90 | 54 | 64 | 26 |
500 | 39.7 | 87 | 47 | 62 | 24 |
Mechanical and thermal properties
Minimum bending radius | during installation: 8 x cable Ø |
static: 4 x cable Ø | |
Permissible temperature range | during installation:0˚ C up to +50˚ C |
static: -20˚ C up to +75˚ C | |
Flame propagation | flame retardant acc. to IEC 60332-1-2 |
General requirements | Dangerous and forbidden substances acc. to RoHS directive (2002/95/EG) are |
not allowed to the manufacturing. |