Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, D/P, D/A, T/T |
Supply Ability: | 10000 set per month |
Place of Origin: | Hubei |
Location: | Wuhan, Hubei, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | VFD, Variable Frequency Drive |
Model No.: | HID600A |
---|---|
Means of Transport: | Ocean, Air, Land |
Type: | DC/AC Inverters |
Output Type: | Triple |
Output Power: | >500W |
Brand Name: | Hiconics |
Size: | costomized |
Weight: | costomized |
Input Voltage: | 380v,660v |
Output Voltage: | 380v,660v |
power range: | 0.4kw-1mw |
control method: | V/F,VC,SVC |
product type: | heavy load type,light load type |
stock temperature: | -25C-+65C |
certificate: | CE,ISO9001:2008 |
delivery port: | Shanghai, Guangzhou |
delivery date: | 7 working days after payment |
application 1: | mining used machinery like ball mill,belt convery |
application 2: | metal processing machinery like lathe machine |
application 3: | oil pump,construction,rubber processing machinery |
Production Capacity: | 10000 set per month |
Packing: | polywood cartoon of different sizes |
Delivery Date: | 7 days after payments |
High Performance Converter,Vector Control Inverter,Static Frequency Converter,Static Inverter,Converter & Inverter
Power Range: 0.4KW~1MW/220V/380V/690V
Product Introduction
Hiconics HID600A Series High-performance Vector VFD can satisfy the current industries requirements: high-performance, high-flexibility and high-expansibility, etc. HID600A can be widely used in AC asynchronous motor, permanent magnet synchronous motor and main motor speed regulation control. This series VFD have many advanced features and adopt the special design, which can supply customerization solutions for users, meanwhile reduce the cost.
Technical Advantages
1. The advanced magnetic field oriented vector control can realize the motor completely decoupling control
2. Composed of vector control (with PG vector control (VC) & without PG vector control (SVC)), torque control (TC) and V/F control as one whole to meet the customers' different needs
3. High speed control: low load capacity, wide speed range, steady speed, high precision, fast response speed.
4. High performance current control: Current fast response, high control precision, with excellent torque control performance.
5.Vector V/F control adopted
6. Superior transient current and voltage control, anti-overvoltage, over current significant effect, to ensure maximum safety without tripping operation.
7. Abundant application features
8. Automatic motor parameter identification algorithm that can automatically identify the motor electrical parameters for the realization of high-performance vector control basis
Technical Parameters
Items | Specification | |
Control Performance | Frequency control range | 0~300Hz |
Output frequency precision | 0.01Hz | |
Frequency resolution preset | Digital set: 0.01Hz Analog set: AD Conversion precision for 1‰ | |
Control method | Open loop V/F control;open loop vector control(SVC); closed loop vector control(VC) | |
Torque boost | Manual torque adjustable; auto full freque ncy torque boost | |
Start torque | G: 0.5Hz 150% (SVC); 0Hz 180% (VC) P: 0.25Hz 100% | |
Speed control range | 1:200 (SVC), 1:1000 (VC) | |
Speed control precision | ±0.5%(SVC), ±0.02% (VC) | |
Torque control precision | ±5%(VC) | |
Over load capacity | G :150% rated current 60s;180% rated current 1s | |
P:120%rated current 60s;150%rated current 1s | ||
Texile swing frequency control | A variety of triangular wave frequency control function
| |
Fixed length control | Rated length control | |
Timing control | Set time range | |
Function Description | V/F curve | 3 methods: linear; multi point; square V/F curves |
DC braking | Dc braking frequency:0.00 hz~max ; Braking time:0.0s~36.0s;braking time:0.0%~100% | |
Inching control | Control frequency:0.00~50.00Hz;control time :0.0s~3000.0s | |
PLC multi-speed operation | To achieve a maximum of 16 speed running through the built-in PLC or control terminals | |
Build-in PID | Convenient to realize process control closed loop control system | |
Auto adjust voltage (AVR) | Automatically keep power constant when the gird voltage changes | |
Acceleration-deceleration curve | Straight line or S line acceleration-deceleration; four kinds of acceleration-deceleration time; 0.1~3200.0s constant adjustment | |
Point start function | Point start frequency: 0.00~50.00hz; point start acceleration-deceleration: 0.1~3200.0s constant adjustment | |
Standard function | Motor parameter auto inspection; open/closed loop vector control;multi-point V/F wave; manual toque boost, jump frequency; carrier frequency auto adjustment; DC brake; DC stop; self start after voltage recover;auto fault reset;16 digital speed running; simple PLC operation; swing frequency for textile; close loop PID adjustment control | |
Control features | Auto torque boost; auto speed difference compensation; auto stable output voltage; speed track start; acceleration over current hold-up; constant speed over current frequency reduction; deceleration over voltage hold-up; auto energy saving operation | |
Operation order channel | 3 control modes:keypad ,terminal, series communication control | |
Frequency source option | Digital set, analog voltage set, analog current set, series communication set, available to switch | |
Frequency source | 10 kinds of frequency source: given digital, analog voltage, current, pulse given simulation given, serial port is given. Through a variety of mode switching | |
Auxiliary frequency source | 10 kinds of frequency source, can be flexibly to realize the frequency tuning, frequency synthesis | |
Input terminal | 6 digital input terminals, extendable to 10 loops, 40 custom function, compatible with PNP or NPN input; one of them can do high frequency pulse input (0~50kHz); 2 analog input terminals, receive voltage signal 0-10V or current signal 0-20mA; extendable to 3 loops | |
Output terminal | 2 open-collector output, 22 custom functions; extendable to 3 loops | |
2 relay output, 22 custom function; extendable to 3 loops | ||
2 analog output, 13 custom function; can output voltage signal 0-10V or current signal 0-20mA; extendable to 2 loops | ||
1 high pulse output (0~50kHz); 13 custom function | ||
Protection function | Over voltage protection; under voltage protection;over current protection;modular protection; radiator over temperature protection; motor over load protection; external fault protection; input power abnormal; output phase loss ;EEPROM abnormal; relay abnormal | |
Display | LED display | Display parameters and copy |
LCD display | Option .English/Chinese ,parameters copy | |
Operation ambient | Protection level | IP20 |
installation | Well installed in cabinet, no dust, no corrosive gas, no flammable gas, no oil fog, no steam, no drop water, no direct sun light | |
Ambient temperature | -10°C~+40°C(derating use if ambient temperature higher than 40 degree, maximum is 50 degree. 1% derating every 1 degree higher than 40 degree. | |
Altitude | 0~2000 m, derating use above 1000 m, rated output current reduce 1% every 100 m higher | |
Relative humidity | 20%~90%RH( no condensation) | |
Vibration | <5.8m/s^2(0.6g) | |
Stock temperature | -25°C~+65°C |
Product Model
Model | Load: constant torque/heavy load | Breaking unit | ||
Over load:150% rated current 60s;180% rate current 1s | ||||
Rate output power (kW) | Rated input(A) | Rated output current(A) | ||
HID600A-T4 series(input voltage:3AC 380V±15%) | ||||
HID600A-T4-0.4G | 0.4 | 1.9 | 1.5 | Standard built-in |
HID600A-T4-0.75G | 0.75 | 3.5 | 2.6 | Standard built-in |
HID600A-T4-1.1G | 1.1 | 4.3 | 3.2 | Standard built-in |
HID600A-T4-1.5G | 1.5 | 5 | 3.8 | Standard built-in |
HID600A-T4-2.2G | 2.2 | 5.8 | 5.5 | Standard built-in |
HID600A-T4-3.7G | 3.7 | 10 | 9 | Standard built-in |
HID600A-T4-5.5G | 5.5 | 15 | 13 | Standard built-in |
HID600A-T4-7.5G | 7.5 | 20 | 17 | Standard built-in |
HID600A-T4-11G | 11 | 26 | 25 | Standard built-in |
HID600A-T4-15G | 15 | 35 | 32 | Standard built-in |
HID600A-T4-18.5G | 18.5 | 38 | 37 | Standard built-in |
HID600A-T4-22G | 22 | 46 | 45 | Built-out |
HID600A-T4-30G | 30 | 62 | 60 | Built-out |
HID600A-T4-37G | 37 | 76 | 75 | Built-out |
HID600A-T4-45G | 45 | 90 | 90 | Built-out |
HID600A-T4-55G | 55 | 105 | 110 | Built-out |
HID600A-T4-75G | 75 | 140 | 150 | Built-out |
HID600A-T4-90G | 90 | 160 | 176 | Built-out |
HID600A-T4-110G | 110 | 210 | 210 | Built-out |
HID600A-T4-132G | 132 | 240 | 250 | Built-out |
HID600A-T4-160G | 160 | 290 | 300 | Built-out |
HID600A-T4-185G | 185 | 330 | 340 | Built-out |
HID600A-T4-200G | 200 | 370 | 377 | Built-out |
HID600A-T4-220G | 220 | 410 | 420 | Built-out |
HID600A-T4-250G | 250 | 460 | 480 | Built-out |
HID600A-T4-280G | 280 | 500 | 540 | Built-out |
HID600A-T4-315G | 315 | 580 | 600 | Built-out |
HID600A-T4-355G | 355 | 620 | 670 | Built-out |
HID600A-T4-400G | 400 | 670 | 750 | Built-out |
HID600A-T4-450G | 450 | 780 | 850 | Built-out |
HID600A-T4-500G | 500 | 835 | 930 | Built-out |
HID600A-T4-560G | 560 | 920 | 1050 | Built-out |
HID600A-T4-630G | 630 | 1050 | 1170 | Built-out |
HID600A-T7 series(input voltage:3AC 660V±15%) | ||||
HID600A-T7-18.5G | 18.5 | 28 | 22 | Built-out |
HID600A-T7-22G | 22 | 40 | 28 | Built-out |
HID600A-T7-30G | 30 | 47 | 35 | Built-out |
HID600A-T7-37G | 37 | 55 | 45 | Built-out |
HID600A-T7-45G | 45 | 65 | 52 | Built-out |
HID600A-T7-55G | 55 | 85 | 63 | Built-out |
HID600A-T7-75G | 75 | 95 | 86 | Built-out |
HID600A-T7-90G | 90 | 100 | 98 | Built-out |
HID600A-T7-110G | 110 | 118 | 121 | Built-out |
HID600A-T7-132G | 132 | 145 | 150 | Built-out |
HID600A-T7-160G | 160 | 165 | 175 | Built-out |
HID600A-T7-185G | 185 | 190 | 198 | Built-out |
HID600A-T7-200G | 200 | 210 | 218 | Built-out |
HID600A-T7-220G | 220 | 230 | 240 | Built-out |
HID600A-T7-250G | 250 | 255 | 270 | Built-out |
HID600A-T7-280G | 280 | 290 | 305 | Built-out |
HID600A-T7-315G | 315 | 340 | 350 | Built-out |
HID600A-T7-355G | 355 | 380 | 390 | Built-out |
HID600A-T7-400G | 400 | 410 | 430 | Built-out |
HID600A -T7-450G | 450 | 460 | 480 | Built-out |
HID600A -T7-500G | 500 | 520 | 540 | Built-out |
HID600A -T7-560G | 560 | 580 | 600 | Built-out |
HID600A -T7-630G | 630 | 660 | 680 | Built-out |
HID600A -T7-800G | 800 | 867 | 824 | Built-out |
Trade Terms
a. Delivery term
We will delivery for you after you done the full payment within 3 to 15 working days
b. Payment
For small order by air or by express, it is 100% T/T in advance.
For large order by ocean, 30% deposit of the order value should be paid, 70% of the balance payment should be done before delivery
c. Packing
Unless otherwise stated in the offer, the prices include packing in accordance with CHINSC'S customary standard of packing
Certificcate