Place of Origin: | Zhejiang |
---|
Location: | Wenzhou, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Mini Circuit Breaker |
Model No.: | JKL7F/5F/68/58 |
---|
Industrial Intellect Reactive Power Auto Compensation Controller DC 12V
Application
JKL7F/5F/68/58 series reative power auto-compensate controller adopted the modern advanced monolithic machine technollgy, has the features of the compact structure, strong anti-reference power, easy operation, installation and application. The products have four series and more than ten types, three hole size, that suit for the industrial and mining focus or disperse reactive compensate, line or pole transformer reactive compensate, the dynamic or static state.
Technical function
The easy operative user's interface
Automatic CT polar check
The power supply disconnected, the whole put-in capacitor removed
The data store would not lose with the disconnection of the power supply
The over-voltage protection
Keep the tangent time gap
Non-vibration with low load
Meet to ZBK44001-89 and DL/T579-96 standard
Technical parameters
Working voltage |
380V±15% |
Frequency |
50Hz |
Input current |
0~5A |
Output power |
3A/250V or 30mA/12V |
Enveironment temperature |
-10~+50 |
Install size |
72×72mm Depth 113mm |
96×96mm Depth 113mm |
|
120×120mm Depth 130mm |
Function
JKL7F-12 |
Three controlling type to select:automatic, half-automatic and manual |
The setting display of the relevant auto-adaptability, power factor, time-dalay, over-voltage and way, Manual anto-set state display |
|
JKL7F-12JBM |
Outlet follows the code type:1:2:2:2:2 1:2:4:4: 1:2:4:8 |
JKL7F-12JRS |
With RS485 communcation nozzle, the data store up for 60 days, equipped with electric inspection |
JKL5F-10 |
Standard self-put threshold setting display of the power factor, time-delay, over-voltage and way |
JKL5F-12 |
Standard self-put threshold setting display of the power factor, time-delay, over-voltage and way |
JKL5F-10DSK |
The real time dynamic controlling response time is 20ms-100ms with each way 12V 30mA |
JKL5F-10JKS |
The quick put type power factor is less than 0.90, the put time is 2S and outlet with relay |
JKL5F-18 |
The max. Outlet way is 18 ways AND CAN BE SET FROM 13 TO 18 BY THE USER |
JKL5F-3×4 |
The subdivided compensate display the power factor, the current, the active and reactive power |
JKL68-10 |
Standard self-put threshold setting display of the power factor,time-delay, over-voltage and way |
JKL68-10DSK |
The real time dynamic controlling response time is 20ms-100ms with each way 12V 30mA |
JKL68-10JKS |