user login

GDVA-404 CTPT tansformer Analyzer/laboratory equipment

100.0~4000.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: T/T
Supply Ability: 300 sets per month
Place of Origin: Chongqing

Company Profile

Location: Chongqing, China (Mainland)
Business Type: Manufacturer
Main Products: Oil Tester , Electric Tester, Oil Purifier

Product Detail

Model No.: GDVA-404
Means of Transport: Ocean, Air
Power: Electronic
Brand Name: Gold
Production Capacity: 300 sets per month
Packing: Standard wooden case
Delivery Date: 10 working days
Show

Product Description

GDVA-404 CTPT Tansformer  Analyzer

 

I Introduction

 

GDVA-404 CT PT Analyzer is performing excitation, ratio and phase error, polarity, secondary loop burden and coil resistance on current and voltage transformer. The instrument provides fully automatic testing and calibration for all types of low leakage flux current transformer and inductive voltage transformer. The maximum knee point voltage of sample CT could be reached 8.4kv.
The standards support by GDVA-CT PT Analyzer include IEC60044-1, IEC60044-2, IEC60044-6 and C57.13

 

 

II Technical  Parameter

 

 

ModelGDVA-404 CTPT Analyzer
Test standardsIEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
Power supplyAC220V±10%,50Hz/60Hz±10%
Power output0.1~125V (AC)
Current output0.001~5A(RMS)
Power output300VA
Maximum knee voltage measurement45kv
Current measurementRange:0~10A (automatically change range in 0.1/0.4/2/10A)           
Error <±0.1%+0.01%FS
Voltage measurementRange:0~200 V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
Turns ratio measurementRange :1~30000
1~2000 error<0.05%
2000~5000 error>0.1%
5000~30000 error<0.2%
Phase measurementerror:±2min,resolution:0.01min
Coil resistance measurementRange:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS
Maximum resolution:0.1mΩ
Temperature measurement   -50~100 Celsius degree, error<3 Celsius degree
CT Secondary burdenRange 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution 0.001ohm
PT Secondary burdenRange 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
PT ratio measurementRange :1~30000
1~5000 error<0.2%
5000~30000 error<0.5%
Saved data groups>1000groups
Work conditionTemperature:-10ºC~50ºC, moist:≤90%
Size485mm×356mm×183mm
Weight<15Kg

 

 

 


 


III  Packing &Delivery


 

 

Payment & Shipping Terms

Supply Capacity

Payment term :

T/T or L/C

Production capacity :

500pcs/month

MOQ:

1 pc

Packing :

 Wooden case

Price

negotiable

Delivery way

 By Air

Means of transport :

FOB , CIF , CFR

Delivery time :

10 days


Post Buying Request