Min. Order: | 10 Set/Sets |
---|---|
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 60000 sets |
Place of Origin: | Jiangsu |
Location: | Huai'an, Jiangsu, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Flowmeter, Pressure Gauge, Control Valve And Etc. |
Means of Transport: | Ocean, Air |
---|---|
Brand Name: | KCCV |
Production Capacity: | 60000 sets |
Packing: | wooden case |
Delivery Date: | 7 days |
DESCRIPTION OF PRODUCTS
Electromagnetic flowmeter is a kind of inductional instrument designed by Faraday's law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realize digital excitation and employs CAN local fieldbus.
Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Electromagnetic flow meters are widely used in industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and removal etc.
Besides measuring flow of general conductive liquid electromagnetic flowmeter can measure flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali.
CLASSIFICATION OF PRODUCTS
Series smart electromagnetic flow meters consist of sensor and smart signal transducer. And it can be classified into two structures--- integral type and remote type according to the set-up form of the sensor and transducer. In terms of integral type electromagnetic flow meters, transducer and sensor directly assembles as a whole and can not be dissociated. It is usually used at the scene where the environmental situation is good. To remote type electromagnetic flow meters transducer composes a product through a special electric cable and sensor. The sensor is installed at the scene and the transducer is installed in the place where the conditions are good. It is usually used at the scene where the environmental situation is poor, such as underground wells, high temperature and the place where people can not reach.
PERFORMANCES & FEATURES
1. Simple structures, firm, no movable parts and long operation life
2. No intercepting fluid parts, no pressure loss and fluid clogging
3. No mechanical inertia, quick response and good stability, application in automatic examination, adjustment and controlling
4. Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity, density and pressure.
5. Employ Teflon or rubber liner and different combination of electrode material such as Hastelloy C, Hastelloy B, 316L, Titanium and adapt the need of different mediums.
6. Supply many styles of flowmeters such as inline type and insertion type, etc.
7. Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.
8. Integral type flowmeters and remote type flowmeters.
9. LCD back light display with high clearness
TECHNICAL DATA
Suitable Diameter | DN25~DN2600 (below DN25 non-standard) |
Electrodes Materials | 316L (stainless steel), Hastelloy C, Hastelloy B, Titanium, Tantalum |
Suitable Fluid | Liquid with conductive ratio more than 5 μs/cm |
Measuring Range | 0.1~10m/s (extendable to 15m/s) |
Upper Limit of Span | 0.5~10m/s. 1~5m/s recommended |
Accuracy | 0.3%, 0.5%,1.0% |
Output Signals | 4~20mADC, load<= 750ohm, 0~3kHz, 5V with source and changeable width. high terminal and effective frequency output , RS485 interface |
Operation Pressure | 1.0MPa, 1.6MPa, 4.0MPa, 16MPa (special) |
Fluid Temperature | -20C~80C, 80C~130C,130C~180C Depending on Lining Material |
Ambient Temperature | Sensor -40C~80C. transducer -15C~50C |
Ambient Humidity | <= 85%RH (at 20C) |
Cable Outlet Size | M20*1.5 |
Power Supply | 220VAC+-10%, 50Hz+-1Hz, 24VDC+-10% |
Power Consumption | <=8W |
Protection Ratings | Integral type: IP65. remote type: sensor IP68,transducer IP65 |
Materials of Liner | PTFE, soft rubber, hard rubber, PFA, etc |
Connection of Flange | National Standard GB9119-88(DIN2051,BS4504) |
Earthing Materials | 316L (stainless steel), HC, Ti, Ta, Cu |
Please contact us for more details.
Generally, we require the following information to select the model:
1) Fluid name:
2) Pipe size:
3) Pipe material:
4) Flow range:
5) Temperature:
6) Operating Pressure:
7) Process connection:
8) Output: