user login

OTDR TECO Single-mode & Multi-mode Optical Time Domain Reflectometer fiber optic tester

1750.0 USD
Min. Order: 1 Set/Sets
Payment Terms: T/T, WU, Money Gram
Supply Ability: 5000 sets /month
Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: TE800
Means of Transport: Ocean, Air, Land
Brand Name: TECO
SM & MM: Yes
Pon OTDR: Optional
Connector: FC
Color: Blue
VFL: Support
SD card interface: Support
USB interface: Support
Ethernet interface: Support
Production Capacity: 5000 sets /month
Packing: Cartons
Delivery Date: 2-3 days
Show

Product Description

OTDR TE800 Single-mode & Multi-mode Optical Time Domain Reflectometer  fiber optic tester


Technical Specifications

Wavelength   (nm)

850/1300

1310/1550

1310/1490/1550

1625

Dynamic   range (dB)2

23/21

32/30

34/32

36/34

38/36

34/32/32

38/36/36

304

325

344

365

Pulse width (ns)

5,20,40,80,160,320,640,1280

5,20,40,80,160,320,640,1280,2560,5120,10240,20480

Event   blind zone (m)3

2m

2m

Attenuation   blind zone (m)3

9m

9m

Linearity   (dB/dB)

±0.05   dB/ dB

Loss   threshold (dB)

0.05

Loss   resolution ratio (dB)

0.01

Sampling   resolution ratio (m)

0.125 to   8

Sampling   point

32K

Distance   uncertainty  (m)

±(1   m + 5×10-5× distance + sampling interval)

Distance   scope (km)

0.3   to180

Typical   real-time refreshing duration

0.2

Memory   capacity of trace

SD Card   (2G), > 10000 pieces

Duration   of measurement

Defined   by user; 5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are selectable

General specification


Interface category

Dimension (H×W×D)

150×235×66


Optical   interface

FC/UPC   (PC, and APC are selectable)

Weight

1.5kg


Data   interface

USB interface,   SD card interface

Temperature

Running   temperature -10℃ to 50℃


Memory   temperature -40℃ to 70℃


Visible failure orientation VFL

Relative   humidity

0% to   95% (non condensation)


Wavelength

650nm

Power   supply

Lithium   battery; continuing working duration ≥ 8 hours


Output   power (dBm)

≥-3

Warranty   period

12   months


Maximum   testing distance

3km

Remarks:   1. The technical specification describes the ensured performance of the   instrument when using typical PC model connector to measure. Without considering   the uncertainty caused by optical fiber refractivity.

2. Dynamic range is the data measured under the condition of the maximum   pulse width and 3 minutes of average time. Dynamic range is the data measured   under the condition of 180km/20480ns/3min.

3. Measuring conditions of blind zone: reflection event is   within 4Km, reflection strength < -35dB. Measured by the minimum   pulse width.

4. Dynamic range measured when there is filter.

5. Dynamic range measured when there is no filter.
















 