Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 20 sets one month |
Place of Origin: | Chongqing |
Location: | Chongqing, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Oil Meter |
Model No.: | GD-261A |
---|---|
Means of Transport: | BY EXPRESS, Ocean, Air |
Brand Name: | GOD |
Production Capacity: | 20 sets one month |
Packing: | wooden case |
Delivery Date: | 10 days |
Summary
This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products in the temperature range from 40°C to 360°C.
I. Main technical features
1. Simulation tracking displays function curves of heating up and test time.
2. Equipped with the English prompt function of mis-operation.
3. Equipped with prompt function of test date,test time and other parameters.
4. Automatically calibrate the effect of atmospheric pressure to test and calculate the corrected value.
5. Differential coefficient detection.Automatically correct the system deviation.
6. Automatically open the lid,detect the flash point and print test data.
7. The test arm rises up and lowers down automatically.
8. Igniting with electric igniting gun,forced air cooling.
II. Main technical specifications and parameters
1. Power supply:AC(220±10%)V, 50Hz.
2. Temperature measurement:Measuring range: Room temperature~250°C.
Test range of flash point: 41°C~250°C.
Flash point≤104°C: error ≤2°C
Flash point>104°C: error ≤6°C
Accuracy: 0.1°C
3. Heating rate: Procedure A: (5~6)°C/min
Procedure B:(1~1.6)°C/min
Automatic control and manually adjustable.
4. Stirring rate:(1) Procedure A: (90~120)RPM
(2) Procedure B: (250±10)RPM
Automatic control and manually adjustable.
5. Igniting mode: (1) Igniting source: gas(or other civilian fuels,the same below)
(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
6. Ambient temperature:≤ 40°C
7. Relative humidity:≤ 80%
8. Total power consumption:≤ 350W
The same series products:
Model | GD-261 | GD-261B | GD-261A | GD-261D | GD-5208 | GD-5208A |
Standard | GB/T261 | GB/T261 | GB/T261 | GB/T261 | GB/T5208 | GB/T5208 |
Range | ambient~300°C | ambient~250°C | ambient~250°C | ambient~300°C | -30°C~50°C | 50°C~100°C |
Repeatability | ≤2°C | ≤2°C | Flash point≤104°C, error: 2°C Flash point>104°C, error: 6°C | ≤2°C |
<2°Csame operator) <3°Cdifferent operators) | |
Reproductivity | ≤4°C | ≤4°C | Flash point≤104°C, Error :4°C Flash point>104°C, error:8°C | ≤4°C | ||
Automatic up/down | N | N | Y | Y | N | N |
With microprinter | N | Y | Y | Y | Y | Y |
Display | N | N | Y | Y | Y | Y |
Communication port | N | N | N | Y | N | N |
Sample | Standard oil cup | Standard oil cup | Standard oil cup | Standard oil cup | 2ml | 2ml |