Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, D/P, D/A, T/T, WU |
Supply Ability: | 7/YY |
Place of Origin: | Henan |
Location: | Zhengzhou, Henan, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Main Products: | Dry Mortar Production Line, Dry Mortar Machine, Dry Mortar Plant, Dry Mortar Mixer |
Model No.: | OG |
---|---|
Means of Transport: | Ocean, Air, Land |
Brand Name: | HENAN ORIENTAL |
OUTPUT: | 3 |
TYPE: | FULL AUTOMATIC |
NAME: | Dry mix shotcrete mahcine |
TYPE2: | Dry mix |
Name: | Shotcrete equipment |
Production Capacity: | 7/YY |
Packing: | Wooden case |
Delivery Date: | 5 |
Grouting pumps manufacturers Henan oriental machinery co.,ltd. Full hydraulic piston grouting pump for the processing of high pressure grouting. The machine has two oulet & inlet, suitable for grouting with two different slurries. Because of the high pressure and long transport distance, it can be widely used for tunnels, slope, mining, bridge and all sorts of underground engineering etc.
Hydraulic drive grouting pump are a universal high-pressure grouting pump and is used for grouting in soil, earth foundation stabilization, waterproofing, tunnel lining, underwater foundations, bridge decks, deep well casing, slope line grouting, etc.
Use manual grout pump
Manual grout pump advantages:
1 no electricity, small size, light weight, easy to move
2 simple structure, durable, easy maintenance
3 manual operation, high pressure grouting can control the speed and volume.
Use manual grout pump
1.the manual grout pump rocker assembled, connect the suction tube and a feeding tube.
2.before using the grout pump at the filling amount of grease on the piston (butter), uniform shaking the handle to ensure that the use of flexible and prevent corrosion.
3.the suction tube is inserted into the barrel, rocker rocking back and forth, you can start grouting.
4. out of the barrel of the joints using pipe clamps tightened with the pump seal connections.
Suction if found poor performance should take the following measures:
(1) Check the feed end of the connector parts fastening seal.
(2) check whether there is damage to the feeding tube leaks.
(3) check whether there is material within the barrel.
(4) Check the discharge port is loose, with or without clogged.
Adverse found the material to take the following measures:
(1) Check the discharge pipe is blocked or not.
(2) the discharge valve is opened or not.