user login

10kv xlpe insulated xlpe insulated overhead abc cable

0.1~100.0 USD
Min. Order: 500 Meter
Trade Term: CIF
Payment Terms: L/C, T/T, WU
Supply Ability: 120000 kilometers/year
Place of Origin: Henan

Company Profile

Location: Zhengzhou, Henan, China (Mainland)
Business Type: Manufacturer
Main Products: Low Voltage Twisted Abc Cable, Types Of Acsr Conductors, Acsr Dog Conductor Price

Product Detail

Model No.: KT-abc
Means of Transport: Ocean
Application: Overhead
Type: Low Voltage
Insulation Material: XLPE
Jacket: PE
Conductor Material: Aluminum
Brand Name: Kington
Color: Black,Red or as your request
Standard: IEC60502,NF C33-209
Quality: High-quality
Production Capacity: 120000 kilometers/year
Packing: wooden drum or as your requirment
Delivery Date: 1-30 days(depend on the order quantity)
Show

Product Description

Insulated Overhead Cable is mainly used for electric power transmission, rebuilding of urban and forest regions.

1. Rated voltage: U0/Uis 1KV.

2. The long term working temperature of the conductor: the temperature of PVC and PE insulated conductor should be less then 70°C; and XLPE conductor should under 90°C.

3.The laying temperature should higher than -20.

The detail technical data of the products: 

Type

Number of Cores

Section Area

JKVS

4

1-150

JKLVS

3+1

4-150

JKYS JKYJS

4

1-150

JKLYS JKLYJS

3+1

4-150

JKVS JKYS JKYJS

2

1-150

JKLVS JKLYS JKLYJS

2

4-150

  

Core* Section area mm2

Number of core/diameter mm

Thickness of the

 insulation

The resistance of the conductor at  20°C ≤Ω/km

Reference weight kg/km

Main core

The fourth core

3*4+1*2.5

1/2.25+1/1.78

1.0

1.0

7.41

48.3

3*6+1*4

1/2.76+1/2.25

1.0

1.0

4.61

95.5

3*10+1*6

7/1.35+1/2.76

1.0

1.0

3.08

141.2

3*16+1*10

7/1.70+7/1.35

1.2

1.2

1.91

215.3

3*25+1*16

7/2.14+7/1.70

1.2

1.2

1.20

289.1

3*35+1*25

7/2.52+7/2.14

1.2

1.2

0.868

382.4

3*50+1*35

7/3.00+7/2.52

1.4

1.4

0.614

526.0

3*70+1*50

19/2.14+7/3.00

1.4

1.4

0.443

655.0

3*95+1*70

19/2.52_19/2.14

1.6

1.6

0.320

886.6

3*120+1*95

37/2.03+19/2.52

1.6

1.6

0.253

1075.7

3*150+1*120

37/2.52+37/2.03

1.8

1.8

0.206

1320.8

1). Standard of abc cable: IEC60502, NF C33-209, GB 12527-90 ASTM

2). Rated voltage: 0.6/1kV,10kV

3). Specification: Concentric strand aluminum wires conductor(AAC or AAAC Conductor),XLPE or HDPE or PVC insulated power cable.

4). Application of abc cable: The cable as a new-type aerial cable is used for transmitting electric power overhead, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.

Relative manufacturing standards: IEC61089, ASTM B231,  ASTM B232,  BS215, DIN48201, DIN48204

We can also manufacture ABC cable according to customers special requirements.

ABC Cable with AAC message core  

SPEC

mm2

Conductor structure  

Insulation

Material

Insulation

Thickness

(mm)

Approx overall diameter

(mm)

Approx weight

(kg/km)

Phase (compacted Al)

Neutral

(alloy)

No./mm

No./mm

1*16+1*16

7/1.72

7/1.72

XLPE

 

 

(HDPE)

1.2

12.5

110.1

1*25+1*25

7/2.15

7/2.15

1.2

14.9

163.9

1*35+1*35

7/2.54

7/2.54

1.4

17.5

229.0

1*50+1*50

7/2.92

7/2.92

1.4

20.1

300.0

1*70+1*70

19/2.15

19/2.15

1.4

23.6

423.2

1*95+1*95

19/2.54

19/2.54

1.6

27.6

585.4

2*16+1*16

7/1.72

7/1.72

1.2

14.2

175.8

2*25+1*25

7/2.15

7/2.15

1.2

16.7

258.4

2*35+1*35

7/2.54

7/2.54

1.4

19.7

361.2

2*50+1*50

7/2.92

7/2.92

1.4

22.5

472.1

2*70+1*70

19/2.15

19/2.15

1.4

26.1

658.3

2*95+1*95

19/2.54

19/2.54

1.6

30.5

908.2

3*16+1*16

7/1.72

7/1.72

1.2

16.3

241.5

3*25+1*25

7/2.15

7/2.15

1.2

19.1

353.6

3*35+1*35

7/2.54

7/2.54

1.4

22.5

493.5

3*50+1*50

7/2.92

7/2.92

1.4

25.7

644.1

3*70+1*70

19/2.15

19/2.15

1.4

29.7

895.2

3*95+1*95

19/2.54

19/2.54

1.6

34.6

1233.

ABC cable :

1.Applications of XLPE,PVC or PE insulated  ABC Cable  

Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service or construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.

2.Specification of XLPE,PVC or PE  insulated  ABC Cable

service drop cable meets or exceeds the following ASTM specifications:

· B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

· B-231 Aluminum Conductors, Concentric-Lay-Stranded.

· B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).

· B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.

· B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire

3.Construction of XLPE,PVC or PE  insulated  ABC Cable

Conductors are concentrically stranded, compressed 1350 H-19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.

4.Teachnical Data of XLPE,PVC or PE insulated ABC Cable

A.Duplex service drop cable:

Code word: ABC cable Chihuahua, ABC cable Vizsla, ABC cable Harrier, ABC cable Whippet, ABC cable Schnauzer, ABC cable Heeler, ABC cable Pekingese, ABC cable Collie, ABC cable Dachshund, ABC cable Spaniel,  ABC Cable Doberman, ABC cable Malemute, ABC cable Setter, ABC cable Shepherd, ABC cable Eskimo, ABC cable Terrier, AB cable Chow, ABC cable Bull

Code*Word

Phase conductor

Bare Neutral Message

Nominal lay Length

Weight Per
1000 ft.(lbs.)

Allo wable Amp acitles

Size
(A WG)

Stranding

Insul
Thick(Mils)

Size
(AWG)

Stranding

Rated
Strength
(lbs.)

inches

XLP

POLY

XLP

POLY

AAC Neutral-messenger

Pekingese

6

1

45

6

7

563

10.36

61

61

85

70

Collie

6

7

45

6

7

563

10.36

64

64

85

70

Dachshund

4

1

45

4

7

881

10.36

92

92

115

90

Spaniel

4

7

45

4

7

881

10.36

96

96

115

90

Doberman

2

7

45

2

7

1350

14.88

147

147

150

120

Malemute

1/0

9

60

1/0

7

1990

14.88

234

234

205

160

B.Triplex service drop cable

Code word: ABC cable Minex, ABC cable Hippa, ABC cable Prawn, ABC cable Barnacle, ABC cable Shrimp, ABC cable Gammarus, ABC cable Leda, ABC cable Dungenese, ABC cable Cyclops, ABC cable Flustra, ABC cable Lepas, ABC cable Artemia, ABC cable Crab, ABC cable Solaster, ABC cable Sandcrab, ABC cable Echinus, ABC cable Fulgar, ABC cable Arca, ABC cable Patella, ABC cable Oyster, ABC cable Clam, ABC cable Murex, ABC cable Purpura, ABC cable Nassa, ABC cable Melita, ABC cable Portunus, ABC cable Nannynose, ABC cable Paludina, ABC cable Voluta , ABC cable Whelk, ABC cable Periwinkle, ABC cable Conch, ABC cable Neritina, ABC cable Cenia, ABC cable Runcina, ABC cable Triton, ABC cable Mursia, ABC cable Zuzara, ABC cable Limpet, ABC cable Scallop, ABC cable Strombus, ABC cable Cockle, ABC cable Janthina, ABC cable Ranella, ABC cable Cavolinia, ABC cable Clio, ABC cable Aega, ABC cable Cerapus

Code*Word

Phase conductor

Bare Neutral Message

Nominal lay Length

Weight Per
1000 ft.(lbs.)

Allo wable Amp acitles

Size
(A WG)

Stranding

Insul
Thick(Mils)

Size
(AWG)

Stranding

Rated
Strength
(lbs.)

inches

XLP

POLY

XLP

POLY

AAC Neutral-messenger

Pateela

6

7

45

6

7

563

14.88

103

103

85

70

Oyster

4

7

45

4

7

881

14.88

154

154

115

90

Clam

2

7

45

2

7

1350

20.58

233

233

150

120

Murex

1/0

7

60

1/0

7

1990

20.58

374

374

205

160

Purpura

1/0

9

60

1/0

7

1990

20.58

368

368

205

160

Nassa

2/0

7

60

2/0

7

2510

25.42

462

462

235

185

Melita

3/0

17

60

3/0

19

3310

29.97

562

562

275

215

Portunus

4/0

18

60

4/0

19

4020

29.97

696

696

315

245

Nannynose

336.4

19

60

336.4

19

6146

38.79

1118

1118

420

325

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun.

C.Quadruplex service drop cable

Code word: ABC cable Bay, ABC cable French Coach, ABC cable German Coach, ABC cable Arabian, ABC cable Belgian, ABC cable Shetland, ABC cable Thoroughbred, ABC cable Trotter, ABC cable Walking, ABC cable Clydesdale, ABC cable Pinto, ABC cable Mustang, ABC cable Criollo, ABC cable Percheron, ABC cable Hanovarian, ABC cable Oldenburg, ABC cable Lippizaner, ABC cable Morochuca, ABC cable Chola, ABC cable Morgan, ABC cable Hackney, ABC cable Palomino, ABC cable Costena, ABC cable Grullo, ABC cable Suffolk, ABC cable Appaloosa, ABC cable Gelding, ABC cable Bronco

Code*Word

Phase conductor

Bare Neutral Message

Nominal lay Length

Weight Per
1000 ft.(lbs.)

Allo wable Amp acitles

Size
(A WG)

Stranding

Insul
Thick(Mils)

Size
(AWG)

Stranding

Rated
Strength
(lbs.)

inches

XLP

POLY

XLP

POLY

AAC Neutral-messenger

Clydessdale

4

1

45

4

7

881

20.58

198

198

100

80

Pinto

4

7

45

4

7

881

20.58

211

211

100

80

Mustang

2

7

45

2

7

1350

25.42

318

318

135

105

Criollo

1/0

9

60

1/0

7

1990

25.42

503

503

180

140

Percheron

2/0

11

60

2/0

7

2510

29.97

619

619

205

160

Hanovarian

3/0

17

60

3/0

19

3310

35.18

764

764

235

185

Oldenburg

4/0

18

60

4/0

19

4020

35.18

945

945

275

210

Lippizaner

336.4

19

80

336.4

19

6146

38.79

1519

1519

370

280

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun

ABC Cable NFC 33-209

 3x35+54.6+16  3x50+54.6+16  3x70+54.6+16 3x95+70+16  3x120+70+16 3x150+70+16 mm2

 2x16mm2 2x25mm2 2x35mm2 2x50mm2 4x16mm2 4x25mm2 4x35mm2

 

10kv xlpe insulated xlpe insulated overhead abc cable10kv xlpe insulated xlpe insulated overhead abc cable10kv xlpe insulated xlpe insulated overhead abc cable10kv xlpe insulated xlpe insulated overhead abc cable10kv xlpe insulated xlpe insulated overhead abc cable10kv xlpe insulated xlpe insulated overhead abc cable

Post Buying Request