Min. Order: | 500 Meter |
---|---|
Trade Term: | CIF |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 120000 kilometers/year |
Place of Origin: | Henan |
Location: | Zhengzhou, Henan, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Low Voltage Twisted Abc Cable, Types Of Acsr Conductors, Acsr Dog Conductor Price |
Model No.: | KT-abc |
---|---|
Means of Transport: | Ocean |
Application: | Overhead |
Type: | Low Voltage |
Insulation Material: | XLPE |
Jacket: | PE |
Conductor Material: | Aluminum |
Brand Name: | Kington |
Color: | Black,Red or as your request |
Standard: | IEC60502,NF C33-209 |
Quality: | High-quality |
Production Capacity: | 120000 kilometers/year |
Packing: | wooden drum or as your requirment |
Delivery Date: | 1-30 days(depend on the order quantity) |
PVC/XLPE Insulated Aluminum conducor ABC Cable
Insulated Overhead Cable is mainly used for electric power transmission, rebuilding of urban and forest regions.
1. Rated voltage: U0/Uis 1KV.
2. The long term working temperature of the conductor: the temperature of PVC and PE insulated conductor should be less then 70°C; and XLPE conductor should under 90°C.
3.The laying temperature should higher than -20.
The detail technical data of the products:
Type | Number of Cores | Section Area |
JKVS | 4 | 1-150 |
JKLVS | 3+1 | 4-150 |
JKYS JKYJS | 4 | 1-150 |
JKLYS JKLYJS | 3+1 | 4-150 |
JKVS JKYS JKYJS | 2 | 1-150 |
JKLVS JKLYS JKLYJS | 2 | 4-150 |
Core* Section area mm2 | Number of core/diameter mm | Thickness of the insulation | The resistance of the conductor at 20°C ≤Ω/km | Reference weight kg/km | |
Main core | The fourth core | ||||
3*4+1*2.5 | 1/2.25+1/1.78 | 1.0 | 1.0 | 7.41 | 48.3 |
3*6+1*4 | 1/2.76+1/2.25 | 1.0 | 1.0 | 4.61 | 95.5 |
3*10+1*6 | 7/1.35+1/2.76 | 1.0 | 1.0 | 3.08 | 141.2 |
3*16+1*10 | 7/1.70+7/1.35 | 1.2 | 1.2 | 1.91 | 215.3 |
3*25+1*16 | 7/2.14+7/1.70 | 1.2 | 1.2 | 1.20 | 289.1 |
3*35+1*25 | 7/2.52+7/2.14 | 1.2 | 1.2 | 0.868 | 382.4 |
3*50+1*35 | 7/3.00+7/2.52 | 1.4 | 1.4 | 0.614 | 526.0 |
3*70+1*50 | 19/2.14+7/3.00 | 1.4 | 1.4 | 0.443 | 655.0 |
3*95+1*70 | 19/2.52_19/2.14 | 1.6 | 1.6 | 0.320 | 886.6 |
3*120+1*95 | 37/2.03+19/2.52 | 1.6 | 1.6 | 0.253 | 1075.7 |
3*150+1*120 | 37/2.52+37/2.03 | 1.8 | 1.8 | 0.206 | 1320.8 |
1). Standard of abc cable: IEC60502, NF C33-209, GB 12527-90 ASTM
2). Rated voltage: 0.6/1kV,10kV
3). Specification: Concentric strand aluminum wires conductor(AAC or AAAC Conductor),XLPE or HDPE or PVC insulated power cable.
4). Application of abc cable: The cable as a new-type aerial cable is used for transmitting electric power overhead, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204
We can also manufacture ABC cable according to customers special requirements.
ABC Cable with AAC message core
SPEC mm2 | Conductor structure | Insulation Material | Insulation Thickness (mm) | Approx overall diameter (mm) | Approx weight (kg/km) | |
Phase (compacted Al) | Neutral (alloy) | |||||
No./mm | No./mm | |||||
1*16+1*16 | 7/1.72 | 7/1.72 | XLPE
(HDPE) | 1.2 | 12.5 | 110.1 |
1*25+1*25 | 7/2.15 | 7/2.15 | 1.2 | 14.9 | 163.9 | |
1*35+1*35 | 7/2.54 | 7/2.54 | 1.4 | 17.5 | 229.0 | |
1*50+1*50 | 7/2.92 | 7/2.92 | 1.4 | 20.1 | 300.0 | |
1*70+1*70 | 19/2.15 | 19/2.15 | 1.4 | 23.6 | 423.2 | |
1*95+1*95 | 19/2.54 | 19/2.54 | 1.6 | 27.6 | 585.4 | |
2*16+1*16 | 7/1.72 | 7/1.72 | 1.2 | 14.2 | 175.8 | |
2*25+1*25 | 7/2.15 | 7/2.15 | 1.2 | 16.7 | 258.4 | |
2*35+1*35 | 7/2.54 | 7/2.54 | 1.4 | 19.7 | 361.2 | |
2*50+1*50 | 7/2.92 | 7/2.92 | 1.4 | 22.5 | 472.1 | |
2*70+1*70 | 19/2.15 | 19/2.15 | 1.4 | 26.1 | 658.3 | |
2*95+1*95 | 19/2.54 | 19/2.54 | 1.6 | 30.5 | 908.2 | |
3*16+1*16 | 7/1.72 | 7/1.72 | 1.2 | 16.3 | 241.5 | |
3*25+1*25 | 7/2.15 | 7/2.15 | 1.2 | 19.1 | 353.6 | |
3*35+1*35 | 7/2.54 | 7/2.54 | 1.4 | 22.5 | 493.5 | |
3*50+1*50 | 7/2.92 | 7/2.92 | 1.4 | 25.7 | 644.1 | |
3*70+1*70 | 19/2.15 | 19/2.15 | 1.4 | 29.7 | 895.2 | |
3*95+1*95 | 19/2.54 | 19/2.54 | 1.6 | 34.6 | 1233. |
ABC cable :
1.Applications of XLPE,PVC or PE insulated ABC Cable
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service
for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed
75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
2.Specification of XLPE,PVC or PE insulated ABC Cable
service drop cable meets or exceeds the following ASTM specifications:
· B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
· B-231 Aluminum Conductors, Concentric-Lay-Stranded.
· B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
· B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
· B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire
3.Construction of XLPE,PVC or PE insulated ABC Cable
Conductors are concentrically stranded, compressed 1350 H-19 aluminum. Insulated with either polyethylene or
crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
4.Teachnical Data of XLPE,PVC or PE insulated ABC Cable
A.Duplex service drop cable:
Code word: ABC cable Chihuahua, ABC cable Vizsla, ABC cable Harrier, ABC cable Whippet, ABC cable Schnauzer, ABC cable Heeler, ABC cable Pekingese, ABC cable Collie, ABC cable Dachshund, ABC cable Spaniel, ABC Cable Doberman, ABC cable Malemute, ABC cable Setter, ABC cable Shepherd, ABC cable Eskimo, ABC cable Terrier, AB cable Chow, ABC cable Bull
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per | Allo wable Amp acitles | ||||||
Size | Stranding | Insul | Size | Stranding | Rated | inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Pekingese | 6 | 1 | 45 | 6 | 7 | 563 | 10.36 | 61 | 61 | 85 | 70 |
Collie | 6 | 7 | 45 | 6 | 7 | 563 | 10.36 | 64 | 64 | 85 | 70 |
Dachshund | 4 | 1 | 45 | 4 | 7 | 881 | 10.36 | 92 | 92 | 115 | 90 |
Spaniel | 4 | 7 | 45 | 4 | 7 | 881 | 10.36 | 96 | 96 | 115 | 90 |
Doberman | 2 | 7 | 45 | 2 | 7 | 1350 | 14.88 | 147 | 147 | 150 | 120 |
Malemute | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 14.88 | 234 | 234 | 205 | 160 |
B.Triplex service drop cable
Code word: ABC cable Minex, ABC cable Hippa, ABC cable Prawn, ABC cable Barnacle, ABC cable Shrimp, ABC cable Gammarus, ABC cable Leda, ABC cable Dungenese, ABC cable Cyclops, ABC cable Flustra, ABC cable Lepas, ABC cable Artemia, ABC cable Crab, ABC cable Solaster, ABC cable Sandcrab, ABC cable Echinus, ABC cable Fulgar, ABC cable Arca, ABC cable Patella, ABC cable Oyster, ABC cable Clam, ABC cable Murex, ABC cable Purpura, ABC cable Nassa, ABC cable Melita, ABC cable Portunus, ABC cable Nannynose, ABC cable Paludina, ABC cable Voluta , ABC cable Whelk, ABC cable Periwinkle, ABC cable Conch, ABC cable Neritina, ABC cable Cenia, ABC cable Runcina, ABC cable Triton, ABC cable Mursia, ABC cable Zuzara, ABC cable Limpet, ABC cable Scallop, ABC cable Strombus, ABC cable Cockle, ABC cable Janthina, ABC cable Ranella, ABC cable Cavolinia, ABC cable Clio, ABC cable Aega, ABC cable Cerapus
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per | Allo wable Amp acitles | ||||||
Size | Stranding | Insul | Size | Stranding | Rated | inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Pateela | 6 | 7 | 45 | 6 | 7 | 563 | 14.88 | 103 | 103 | 85 | 70 |
Oyster | 4 | 7 | 45 | 4 | 7 | 881 | 14.88 | 154 | 154 | 115 | 90 |
Clam | 2 | 7 | 45 | 2 | 7 | 1350 | 20.58 | 233 | 233 | 150 | 120 |
Murex | 1/0 | 7 | 60 | 1/0 | 7 | 1990 | 20.58 | 374 | 374 | 205 | 160 |
Purpura | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 20.58 | 368 | 368 | 205 | 160 |
Nassa | 2/0 | 7 | 60 | 2/0 | 7 | 2510 | 25.42 | 462 | 462 | 235 | 185 |
Melita | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 29.97 | 562 | 562 | 275 | 215 |
Portunus | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 29.97 | 696 | 696 | 315 | 245 |
Nannynose | 336.4 | 19 | 60 | 336.4 | 19 | 6146 | 38.79 | 1118 | 1118 | 420 | 325 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) |
C.Quadruplex service drop cable
Code word: ABC cable Bay, ABC cable French Coach, ABC cable German Coach, ABC cable Arabian, ABC cable Belgian, ABC cable Shetland, ABC cable Thoroughbred, ABC cable Trotter, ABC cable Walking, ABC cable Clydesdale, ABC cable Pinto, ABC cable Mustang, ABC cable Criollo, ABC cable Percheron, ABC cable Hanovarian, ABC cable Oldenburg, ABC cable Lippizaner, ABC cable Morochuca, ABC cable Chola, ABC cable Morgan, ABC cable Hackney, ABC cable Palomino, ABC cable Costena, ABC cable Grullo, ABC cable Suffolk, ABC cable Appaloosa, ABC cable Gelding, ABC cable Bronco
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per | Allo wable Amp acitles | ||||||
Size | Stranding | Insul | Size | Stranding | Rated | inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Clydessdale | 4 | 1 | 45 | 4 | 7 | 881 | 20.58 | 198 | 198 | 100 | 80 |
Pinto | 4 | 7 | 45 | 4 | 7 | 881 | 20.58 | 211 | 211 | 100 | 80 |
Mustang | 2 | 7 | 45 | 2 | 7 | 1350 | 25.42 | 318 | 318 | 135 | 105 |
Criollo | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 25.42 | 503 | 503 | 180 | 140 |
Percheron | 2/0 | 11 | 60 | 2/0 | 7 | 2510 | 29.97 | 619 | 619 | 205 | 160 |
Hanovarian | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 35.18 | 764 | 764 | 235 | 185 |
Oldenburg | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 35.18 | 945 | 945 | 275 | 210 |
Lippizaner | 336.4 | 19 | 80 | 336.4 | 19 | 6146 | 38.79 | 1519 | 1519 | 370 | 280 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) |
ABC Cable NFC 33-209
3x35+54.6+16 3x50+54.6+16 3x70+54.6+16 3x95+70+16 3x120+70+16 3x150+70+16 mm2
2x16mm2 2x25mm2 2x35mm2 2x50mm2 4x16mm2 4x25mm2 4x35mm2