 welcome to our factory ,we supply the DUK-2A Wenner electric resistivity system

 


 

 

 it is Widely used for high-resolution research, tomography and monitoring applications.

 Coal mining gobs, caves of Custer area, geological disasters survey like landslides other geological disasters.

 High resolution engineering geological exploration like factory foundations, highways, bridges, railways, civil engineering, hydrology, engineering, environmental.

 For landslides and other geological disaster exploration.

 Metal and non-metallic mineral resources exploration and geothermal exploration

 

Main Features.

 

 Assembly data acquisition devices and multiplexer together in the same case,which not only reduce the volume but also decrease the weight, thus avoid errors caused by operating the devices separately and due to inconformity of switch parameter settings.

 Maintain all functions ofDUK2A  MultiElectrodes Resistivity Survey System and conventional electrical method.  Add high and low current transform taps, add high and low input impedance transformation tap, and improve the acquisition capability of weak signals.

 Add storage and output functions for compensation SP voltage value.

 Adopt 16-bit A/D and 16-bit D/A, thus improve the discernibility for measurement of collected data.

 Add the function for automatically detect grounding resistance before each measurement; give directions for the points exceed the grounding resistance value, for automatically proceeding with further measurement if required; the value at such point can be replaced with a fixed symbol to facilitate the elimination of this point while processing the information and data.

 Greatly enhance the repeatability of measured data. 

 

Technical Specifications

 Conversion Electrodes: 60 channels/120 channels

 Voltage Measuring Range: ±6V

 Voltage Measuring Accuracy: 0.5%, ±1 digit

 Measuring Voltage Resolution: 1μV

 Current Measuring Range: 1μA~2000mA, 1μA~6000mA (two taps)

 Measuring Current Resolution: 1μA

 Measuring Current Accuracy: 0.5%, ±1 digit

 Maximum Power Supply Voltage: 500VDC

 Maximum Power Supply Current: 2A

 Measured Apparent Polarizability Accuracy: ±1%, ±1 digit

 SP Compensation Range: 1000mV

 Input Impedance: 20 MΩ, 100 MΩ (two taps)

 Suppression on 50Hz Power Frequency: better than 80dB

 Storage Capacity: 1MB

 Power Supply: 1# cell, 8 pcs; or external 12V battery (cells to be taken out when use the battery)

 Power Consumption: 250 mA (Standby)

 Working Temperature: -10°C~ +50°C, 95%Rh

 Weight: 8.5 kg

 Volume: 324×240×245mm

 