Liquid Detection Resistivity DZD-6A
1000.0~3000.0 USD
Min. Order: |
1 Set/Sets |
Trade Term: |
FOB |
Payment Terms: |
L/C, D/P, D/A, T/T, WU |
Supply Ability: |
50sets /mouth |
Place of Origin: |
Chongqing |
Company Profile
Location: |
Chongqing, China (Mainland) |
Business Type: |
Manufacturer |
Main Products: |
Geological Exploration Instrument |
Product Detail
Model No.: |
DZD-6A |
Means of Transport: |
Ocean, Air, Land |
Application: |
Others |
Type: |
Others |
Brand Name: |
gold |
Maximum Measuring Voltage: |
-6000mV~+6000mV |
Measuring Voltage Resolution:: |
0.01 mV |
Measuring Voltage Accuracy: |
(at Vp>10mV)±5%, ±1 digit; (at Vp<10mV)±1%, ±1 digit |
Measuring Current Range: |
0~5000 mA |
Measuring Current Resolution: |
0.01 mA |
Production Capacity: |
50sets /mouth |
Packing: |
wooden case |
Delivery Date: |
10DAYS |
Show
Product Description
MainApplications
- By utilizing relevant parameters of apparent resistivity and inducedpolarization method, the instrument is widely used in many aspects includingmetal and non-metal mineral resources exploration, energy exploration, citygeophysical exploration, railway and bridge engineering exploration, etc.
- Search for groundwater, solve the human and animal drinking water issue aswell as industrial and agricultural water issue. Determine the hidden safetyrisk location in reservoir dam foundation and flood-control dyke, find faultagezone and collapse column, landslides, coal mining goaf, search for geothermaland other hydrological, engineering geological exploration.
- Accessories made by our factory with 60-channel or 120-channel multiplexelectrode switch, also can be used for multi-electrode resistivity surveysystem.
Technical Specifications
Receiving Part
- Measuring Voltage Range: -6000mV~+6000mV
- Measuring Voltage Resolution: 0.01 mV
- Measuring Voltage Accuracy: (at Vp>10mV)±5%, ±1 digit; (atVp<10mV)±1%, ±1 digit
- Measured Apparent Polarizability Accuracy: ±1%, ±1 digit
- Measuring Current Range: 0~5000 mA
- Measuring Current Resolution: 0.01 mA
- Measuring Current Accuracy: (at Ip>10mA)±5%, ±1 digit; (atIp<10mA)±1%, ± digit
- Input Impedance: ≥50MΩ
- Interference Suppression on 50Hz Power Frequency: Better than 80dB
Transmitter Part
- Maximum Transmitting Power: 4500 W
- Maximum Power Supply Voltage 900V
- Maximum Power Supply Current: 5A
- Instrument has over-voltage and over-current protection devices
- Power Pulse Width: 1-60 seconds, Duty Cycle 1:1
Others Parameter
- Working Temperature: -10°Cto +50°C, 95%Rh
- Storage Temperature: 20°C to +60°C
- Power Supply: 1# Dry Cell (or rechargeable battery with the samespecification) 8 pcs
- Machine Current: < 55 mA
- Weight: 8 kg
- Volume: 305×200×202 mm