China Professional power plant and industrial CFB boiler

Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: L/C, T/T
Supply Ability: 10sets/month
Place of Origin: Shandong

Company Profile

Location: Qingdao, Shandong, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Biomass Boiler, Gas/oil Boiler, Coal Fired Boiler, Boiler

Product Detail

Model No.: EPG
Means of Transport: Ocean
Structure: Others
Output: Steam
Type: Natural Circulation
Fuel: Others
Style: Horizontal
Pressure: Low Pressure
Usage: Industrial
Brand Name: EPCB
Production Capacity: 10sets/month
Packing: Exporting standard
Delivery Date: 15~30days
Show

Product Description

 Circulating fluidized bed boilers
* circulating fluidized bed boiler are low temperaturecombustion, so emissions of nitrogen oxides is far less than the pulverizedcoal,
the combustion process canachieve direct desulfurization, desulfurization efficiency, and economy oftechnical equipment simple.
* coalcombustion and wide adaptability and high efficiency, low quality coal suitablefor low calorific value.
* discharge ofash activity, and easy to realize the comprehensive utilization of ash nosecondary pollution.
* line regulationrange, low compliance may be reduced to about 30% of full load.
Item\Model
EPG-35/3.82-M EPG-35/5.3-M
EPG-75/3.82-M EPG-75/5.3-M
EPG-130/3.82-M EPG-130/5.3-M
EPG-220/9.8-M
Rated capacity t/h
35
75
130
220
Rated working pressure Mpa
3.82/5.3
3.82/5.3
3.82/5.3
9.81
Rated steam temperature °C
450/500
450/500
450/500
540
Rated feed water temperature °C
150
150
150
215
Boiler heating ares m2
radiation heating surface
188
380.3
777.39
858
Mixes-heating surface
-
-
-
242
Superheater
345.5
633
1089.5
2840
Economizer
663
1448
2721.98
4303
Air preheater
746
1743
2514.5
8746
Fluidized bed area m2
4.43
7.7
15.2
24.556
Design coal type
Soft coal,lean coal,Anthracite,
Design thermal efficiency %
88.3
90
90
89.2
Grain size of coal mm
≤10
≤10
≤8
0~10
Grain size of desulfurizer mm
≤2
≤2
≤1.5
0~1.5
Desulfurization efficiency %
≥80
≥80
≥90
≥90
Ca/S Ratio
2.5
2.5
2.5
2.5
Hot air temperature(primary/secondary air) °C
130/120
145/135
207/201
231/235
Smoke extraction temperature °C
150
150
~140
135
Transportation weight of Max. parts Kg
10488
15538
18485
61718
Outside dimension of after-installed(LxWxH) M
2.7x9.2x14.9
33.85x12x16.25
43.2x11.85x20.93
24.7x23x48.9
Notes:This form only for your reference,if anychanged,please refer to Ex-factory technical documents.

Post Buying Request