Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB,CFR,CIF,DAT,FAS,DDP,DAP,CIP,CPT,FCA,EXW |
Payment Terms: | Paypal, L/C, D/P, D/A, T/T, WU, Money Gram |
Supply Ability: | 50 sets/month |
Place of Origin: | Hong Kong |
Location: | Hong Kong Island, Hong Kong, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company, Distributor/Wholesaler, Service |
Model No.: | AT473 |
---|---|
Means of Transport: | Ocean, Air, Land |
Usage: | Plastic Testing Machine |
Power: | Electronic |
Brand Name: | HY TECH |
Work position: | 6 |
Max. pressure: | 1.6Mpa or customized |
Control Mode: | Touch screen control |
Display: | Large LCD display |
Standard 1: | ISO 10508, 12293 |
Standard 2: | ASTM F 1335-98 |
Standard 3: | BS 7291 |
Standard 4: | DVGW W 534, 542, 543 |
Certificate: | CNAS, CE, CO |
Power supply: | 1Phase, 11/220V, 60/50Hz |
Production Capacity: | 50 sets/month |
Packing: | Wooden box |
Delivery Date: | 6 ~ 8 weeks |
Application:
AT473 Thermal Cycling Tester is designed according ISO and ASTM standard requirement, it's mainly used to check the leakage status of composite pipe & fittings when subjected to specify cycling times under specified internal pressure load. It's widely used in plastic pipe manufacture factory and some Labs.
Standards:
ASTM F 1335-98 | ISO 10508, 12293 | GB/T 18742, 18992, 18993, 18998, 19472 |
CJ/T 138, 175 |
Note: For more standards, please contact us
Features:
1) High temperature and high pressure only exist in the sample and short piping, that all the electric parts in circulation line work at normal pressure to attain a long service life.
2) Testing control and monitoring of individually station takes over PLC and touch screen terminal.
3) Individual circulation time, flow rate and pressure can be selected.
4) Several reliable safeguard, liquid level measuring devices, emergency stop switch and cord switch ensure the tester to be out of action in time if the test fails or piping system bursts. Doors shall be locked during testing period.
5) Pre-stress system was introduced to apply the initial tensile stress. This system is optional.
Technical Specification:
Model | HY4730 |
Max. pressure | 1.6MPa |
Pressure control accuracy | ±0.05Mpa |
Pressure display resolution | 0.001Mpa |
Number of test stations | 6 (can customize) |
Cycle period | 300 ~ 1200s |
Number of cycles | 1 ~ 10,0000 adjustable |
Cold water temperature range | 15℃ ~ R.T adjustable |
Cold water temperature accuracy | ±2℃ |
Hot water temperature range | R.T ~ 98℃ |
Hot water temperature accuracy | ±1℃ |
Temperature display resolution | 1℃ |
Temperature uniformity | ≤±1℃ |
Water flow accuracy | 0.01m/s |
Water flow display resolution | 0.001m/s |
Ambient temperature | 23℃±2℃ |
Max total cross-section diameter of all connect test samples | 6200mm2 (2*Φ63) |
Power supply | 3phase, AC380V, 50Hz, 25KW |
Dimensions | 4600×2900×2000mm |