user login

otdr Optical Time Domain Reflectometer

Place of Origin: Zhejiang

Company Profile

Location: Wenzhou, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Fusion Splicer

Product Detail

Brand Name: techtx

Product Description

 Mail detail :
1, Large touch screen+shortcut keys, easy to operate/
2,Large-capacity polymer lithium battery ,with super long working hours
3,Intelligent testing ,simple use , powerful function.
4,Media of memory card+SD card , with superlarge storage capacity of traces.
5,Able to meet FTTX testing needs .
6,Several wavelengths can be chosen.
7,Solid casing design,dustproof and shockproof.
Technical Specifications1
Wavelength (nm)
850/1300
1310/1550
1310/1490/1550
1625
Dynamic range (dB)2
23/21
32/30
34/32
36/34
38/36
34/32/32
38/36/36
304
325
344
365
Pulse width (ns)
5\20\40\80\160\320\640\1280
5\20\40\80\160\320\640\1280\2560\5120\10240\20480
Event blind zone (m)3
2m
2m
Attenuation blind zone (m)3
9m
9m
Linearity (dB/dB)
±0.05 dB/ dB
Loss threshold (dB)
0.05
Loss resolution ratio (dB)
0.01
Sampling resolution ratio (m)
0.125 to 8
Sampling point
32K
Distance uncertainty  (m)
±(1 m + 5×10-5× distance + sampling interval)
Distance scope (km)
0.3 to180
Typical real-time refreshing duration (s)
0.2
Memory capacity of trace
SD Card (2G), > 10000 pieces
Duration of measurement
Defined by user; 5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are selectable
General specification
Interface category
Dimension (H×W×D)
150×235×66
Optical interface
FC/UPC (PC, and APC are selectable)
Weight
1.5kg
Data interface
USB interface, SD card interface
Temperature
Running temperature -10℃ to 50℃
Memory temperature -40℃ to 70℃
Visible failure orientation VFL
Relative humidity
0% to 95% (non condensation)
Wavelength
650nm
Power supply
Lithium battery; continuing working duration ≥ 8 hours
Output power (dBm)
≥-3
Warranty period
12 months
Maximum testing distance
3km
Remarks: 1. The technical specification describes the ensured performance of the instrument when using typical PC model connector to measure. Without considering the uncertainty caused by optical fiber refractivity.
2. Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time. Dynamic range is the data measured under the condition of 180km/20480ns/3min.
3. Measuring conditions of blind zone: reflection event is within 4Km, reflection strength < -35dB. Measured by the minimum pulse width.
4. Dynamic range measured when there is filter.
5. Dynamic range measured when there is no filter.
NO.
Series
Type
Description
Note
1
TC600
MV10A
850/1300MMF+VFL,23/21dB                               
2
TC600
SV20A
1310/1550SMF+VFL,32/30dB                     
3
TC600
SV20B
1310/1550SMF+VFL,34/32dB                        
4
TC600
SV30A
1310/1490/1550SMF+VFL,32/30/30dB          
5
TC600
SS24A
1310/1550SMF+1625SMF,         32/30/30dB                                  
PON OTDR
NO filter
6
TC600
SS24AF
1310/1550SMF+1625SMF,                 32/30/28dB                                   
PON OTDR
filter
7
TC600
SV20C
1310/1550SMF+VFL,38/36dB                     
8
TC600
SV30C
1310/1490/1550SMF+VFL,38/36/36dB           
9
TC600
SS24C
1310/1550SMF+1625SMF,          38/36/36dB                                 
PON OTDR
NO filter
10
TC600
SS24CF
1310/1550SMF+1625SMF,                38/36/34dB                                   
PON OTDR
Filter
Post Buying Request