Handheld Pulse Lightweight Hospital Patient Monitor With Clock

Place of Origin: Zhejiang

Company Profile

Location: Shijiazhuang, Hebei, China (Mainland)
Business Type: Manufacturer
Main Products: Hospital Autoclave Sterilizer

Product Detail

Model No.: PM60A

Product Description

 

Handheld Pulse Lightweight Hospital Patient Monitor With Clock

 

Quick Detail:

Principle of the PM60A patient Monitor is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.


Description:

Small in volume,light in weight and convenient in carrying
Operation of the product is simple ,low power consumption
SpO2 value display
Pulse rate value display, bar graph.displa
Pulse waveform display
The display mode can be changed
With backlight,and changeable backlight-time
A pulse rate sound indication
With measured data overruns limits and low-voltage alarm function,the upper/down alarm range can be adjustable
With clock function
Battery capacity indication
Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage,and with alarm function
Connected with an external oximeter probe
Trend Graph/Table: Resolution from 1s, 5s, 10s,30s,1min,and so on. Storage of latest 96 hours trend data.
Alarm:Adjustable High and Low limits. Three level audible and visual alarm , latest 50 alarm information and  waveform displays 8 seconds which 4 seconds are before a certain time when the alarm is turned on and 4 seconds are after appointed time when the alarm is turned on
Upload data:Data stored in SD card can be uploaded to computer and  analyzed by software "SpO2 Assistant


Specifications:

Display Mode:3.5" Color TFT display
Screen Resolution:320*240
SpO2 Measuring Range:0%100%, (the resolution is 1%).
Accuracy:70%100%:±2% ,Below 70% unspecified.
PR Measuring Range:30bpm250bpm, (the resolution is 1bpm)
Accuracy:±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption:less than 300mA
Voltage: DC 5.0V
Power Supply: Built-in recharge Li-Polymer  
Battery working hour:7 hours
Safety Type:Interior Battery,BF Type

 

Competitive Advantage:

Our company research and development with independent intellectual property rights of patient monitor, technology mature and stable, easy operation, high cost performance, etc. It is through the Chinese many hospitals more than 10 years of clinical tests, get professional certification agency inspection of quality product. Our products sell very good in the international market, please choose to cooperate with us, this is your wise choice. We will use high-quality products, excellent service to prove your wise choice.

 