1.brief product introduction
This product is suitable for linking the household electrical appliance, small electric tools, instruments and power lighting devices with the rated A.C. voltage equal or less than 450/750V. The type, description and applications of the products are listed in the following table.
The operating temperature of the wire is 90℃ or the type of BV-90 and RV-90, 70℃ for the other types.
2.type,description and main qpplication of the PVC insulated wire
Type | Description | Main application |
227 IEC 01(BV) 227 IEC 05(BV) 227 IEC 07(BV-90) 227 IEC 10 (BVV) BLV | Copper/Aluminum core PVC insulated cable | wire fixed and distribute |
BVV BLVV | Copper/Aluminum core PVC insulated sheath flat cylinder soft wires |
BVVB BLVVB | Copper/Aluminum core PVC insulated sheath flat soft wires |
BVR | PVC insulated soft wires with copper core |
227 IEC 02 (RV) 227 IEC 06 (RV) 227 IEC 08 (RV-90) | PVC insulated soft wires with copper core | Suitable for medium or light type movable electrical appliances, instruments, household electrical appliances, power lighting, etc, that need soft area when working. |
227 IEC 52 (RVV) | light type PVC insulation sheathed soft wires |
227 IEC 53 (RVV) | Common PVC insulation sheathed soft wires |
RVVP | Copper-core PVC insulation sheathed shield soft wires. | Suitable for the connection of electric appliances instruments electric equipments and automatic devices with the rated voltage of 300/300V or below. |
3.applications
It applies to electrical appliances, instruments and telecom devices at a rated voltage up to 450/750 volts.
The main features of the flame retardant PVC cable or wire are hard to get fire or that the continuous burning of cables is limited when it is on fire. It applies to the places with special demands for flame retardant property. Flame retardant cable is classified as Class A, Class B and Class C. Among the 3 classes, Class A is the best.
Fire-resistance cable can operate normally for some time when it is burning, apart from that it can transmit electrical power under normal condition. It is used in the places with special demands for fire resistance property. Fire resistance cable has two classes like A and B. Clients can select one as their practical needs.
The main characteristic is low smoke and halogen. Flame retardant cables are low smoke emission and low release of HCL gas besides the property of flame retardant. It can be used in the places with special demands for the density of smoke emission and the release value of HCL gas when the cable gets burning.
4.Main features of cables (wires)
(1) Rated voltage U0/U is 450/750 volt, 300/500volt or 300/300 volt.
(2) Permissible continuous operating temperature of cables are:
——for type of cable RV-105 and BV-105, less than 105℃.
——for the others, less than 70℃.
(3) Ambient temperature should be not less than 0℃, and permissible bending radius of cables for fixed connecting should be as follows during installation:
——for O.D. less than 25mm, equal to or greater 4 times O.D.
——for O.D. more than 25mm, equal to or greater 6 times O.D.
(4) Flame retardant cables should pass the test of bunched cables or wires under fire conditions which are described in the standards of GB1266.5-90 or IEC332-3.
(5)Fire resistance cables should pass the test of fire resistance stipulated in the standards of GB1266.6-90 or IEC331.
(6) Low smoke, low halogen, flame retardant cables should pass the test of flame retardant described in GB12666.5-90 or IEC 332-3. Furthermore, its optic-penetrated rate shall be not less than 35 percent, while the release value of HCL gas not larger than 100mg/g.