user login

bare AAC conductor BS 215 standard Ant/Fly/Butterfly/Midge/Wasp

2.0~66.0 USD
Min. Order: 500 Meter
Trade Term: FOB
Payment Terms: L/C, T/T, WU
Supply Ability: 50000 Kilometers one week
Place of Origin: Henan

Company Profile

Location: Zhengzhou, Henan, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Power Cable, Electric Wire, Rubber Cable, Overhead Cable, Bare Conductor

Product Detail

Model No.: AAC
Means of Transport: Ocean, Air, Land
Application: Overhead
Type: Bare
Insulation Material: Others
Conductor Material: Aluminum
Conductor Type: Stranded
Brand Name: aodian
voltage: LV MV HV
type: stranded
standard: BS215, Part1
place of origin: China
model: AAC
quality: standard
package: wooden drum
OD: 6.18mm---36.6mm
color: Silver or gray
Production Capacity: 50000 Kilometers one week
Packing: standard wooden drum or steel wooden drum
Delivery Date: 15days for one container
Show

Product Description

bare AAC conductor BS 215 standard Ant/Fly/Butterfly/Midge/Wasp

Introductionof
Al-electric All Aluminium Conductors are used in Transmission and Distribution system to carry the generated electrical energy from generating station to end user.
The Electrical energy is normally generated at the power stations far away from the urban areas where the consumers are located. There is a large network of conductors between the generating stations and the consumer.
The network is called the Transmission and Distribution system. The Transmission system is to deliver bulk power from power stations to the load centres and large industrial consumers beyond the economical service range of the regular primary distribution lines where as distribution system is to deliver power from power sector or substations to the various consumers. This transmission and distribution system can employ either overhead system or underground system.

Characters
Transmission of power, overhead system mainly due to low cost and some other advantages.AAC for distribution of power carry out mostly the high voltage transmission. For transmission and distribution of electric power the conductor material used must have the following characteristics:
i) High conducting i.e. low specific resistance
ii) High tensile strength in order to withstand mechanical stress
iii) Low specific gravity in order to give low weight per unit volume
iv) Low cost in order to be used over long distance
v) Should not be brittle
Advantages
Copper, Aluminium, Steel and Steel cored aluminium, galvanised steel conductors are generally employed for this purpose and preferably stranded in order to increase the flexibility (Solid wires, except of smaller sizes, are difficult to handle and when employed for long spans tend to crystallize at the points of support because of the swinging in winds). Stranded conductors usually have a central wire around which there are successive layers of 6, 12, 18, 24 wires. For 19 layers, the total number of individual wire is 3n (n+1). If the diameter of each strand is torn diameter of the stranded conductors will be (2n+1) d. In the process of manufacture adjacent layers are spiraled in opposite direction, so that the layers are bound together. This method of construction is called as Concentric Lay, out of above mentioned conducting materials, Aluminium is widely used due to its cheapness and many others comparative advantages over other conducting materials. The AAC conductors for high voltage transmission have first replaced the bore copper conductors where copper is scarce and costly on the other hand EC grade Aluminium is easily available and as far as the electric properties are concerned, aluminium is equally good being lighter in weight and for same sage span length of the transmission could be increased in comparison to copper.

AAC Bare Conductors BS215, Part1 Specification
Code Name          Al. Area(mm2)           Wire No. &Dia. (mm) SectionArea(mm2) O.D(mm)          Mass(kg/km)    
Midge227/2.0623.336.1864
Aphis257/2.3526.47.273
Gnat257/2.2126.86.673
Weevil303/3.3631.67.986
Mosquito357/2.5937.07.8101
Ladybird407/2.7942.88.4117
Ant507/3.1052.839.30145
Fly607/3.4063.5510.20174
Bluebottle707/3.6673.711.0202
Earwing757/3.7878.511.4215
Grasshopper807/3.9184.111.7230
Clegg907/4.1795.612.5262
Wasp1007/4.39106.013.17290
Beetle10019/2.67106.013.4293
Bee1257/4.90132.014.7361
Cricket1507/5.36157.916.1432
Homet15019/3.25157.616.25434
Caterpillar17519/3.5318617.7512
Chafer20019/3.78213.218.90587
Spider22519/3.99236.920.0652
Cockroach25019/4.22265.721.10731
Butterfly30019/4.65322.723.25888
Moth35019/5.00373.225.01027
Drone35037/3.58373.325.11029
Locust40019/5.36428.526.81179
Centipede40037/3.78415.526.461145
Maybug45037/4.09486.928.61342
Scordion50037/4.27529.529.91460
Cicada60037/4.65628.632.61733
Tarantula70037/5.23794.636.62191
Note: Many other types AAC conductors can be produced by Al-electric.

Photo of the bare AAC conductor BS 215 standard Ant/Fly/Butterfly/Midge/Wasp
bare AAC conductor BS 215 standard Ant/Fly/Butterfly/Midge/Waspbare AAC conductor BS 215 standard Ant/Fly/Butterfly/Midge/Waspbare AAC conductor BS 215 standard Ant/Fly/Butterfly/Midge/Wasp
Post Buying Request