user login

High quality stranded copper conductor XLPE insulated ACSR cable

2.0~66.0 USD
Min. Order: 400 Meter
Trade Term: FOB
Payment Terms: L/C, T/T, WU
Supply Ability: 10000m/week
Place of Origin: Henan

Company Profile

Location: Zhengzhou, Henan, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Power Cable, Electric Wire, Rubber Cable, Overhead Cable, Bare Conductor

Product Detail

Model No.: ABC cable
Means of Transport: Ocean, Air, Land
Application: Overhead
Type: High Voltage
Insulation Material: XLPE
Jacket: PVC
Conductor Material: Aluminum
Brand Name: Aodian
type: XLPE insulated overhead power cable
voltage: high voltage
stranded number: there
standard: IEC, ASTM, ASTM,ANSI,ICEA
Production Capacity: 10000m/week
Packing: standard wooden drum or steel wooden drum
Delivery Date: 15days for one container
Show

Product Description

High quality stranded copper conductor XLPE insulated ACSR cable

Al/XLPE+ACSR 0.6/1kV overhead ABC cable
Triplex/Quadruplex Service Drop
AAC, ACSR conductor
Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE / PE / PVC / LDPE insulation, Aluminum Conductor
Product Description
1. Application of Service Drop Cable:
Service Drop Cable (ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
3. Detailed Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower ATA conductor temperature of 750C maximum.
Construction
Concentric stranded or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
3.2 Triplex Service Drop
Applications
To supply power from the utility`s lines to the consumer`s weather head. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers are concentrically stranded 6210 AAAC, AAC or ACSR.
Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Item#
Phase Conductor
Size AWG
Phase
Conductor
Stranding
PhaseConductor
Insulation Thickness
Bare Neutral
Messenger
Size AWG
Bare
Neutral Strand
Bare Neutral messenger Breaking Strength
Weight Per 1000ft - XLP
Weight Per 1000ft - Poly
Rating - XLP
Rating-Poly
Pekingese
6
Solid
45 mls
6
7/w
563 Lbs
63.5 Lbs
61.7 Lbs
70 Amps
70 Amps
Collie
6
7/w
45 mls
6
7/w
563 Lbs
66.8 Lbs
63.1 Lbs
70 Amps
70 Amps
Dachshund
4
Solid
45 mls
4
7/w
881 Lbs
95.5 Lbs
93.4 Lbs
90 Amps
90 Amps
Spaniel
4
7/w
45 mls
4
7/w
881 Lbs
100.5 Lbs
95.4 Lbs
90 Amps
90 Amps
Doberman
2
7/w
45 mls
2
7/w
1350 Lbs
152.7 Lbs
145.7 Lbs
120 Amps
120 Amps
Malemute
1/0
19/w
60 mls
1/0
7/w
1990 Lbs
242.6 Lbs
234.2 Lbs
160 Amps
160 Amp

s

Potoes of  stranded copper conductor XLPE insulated ACSR cable:


Duplex stranded aluminium conductor XLPE insulation AAC neutral conductor

Duplex stranded aluminium conductor XLPE insulation AAC neutral conductor

Duplex stranded aluminium conductor XLPE insulation AAC neutral conductor

High quality stranded copper conductor XLPE insulated ACSR cable

High quality stranded copper conductor XLPE insulated ACSR cable
Post Buying Request