Min. Order: | 3 Kilometer |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 5000 kilometers |
Place of Origin: | Henan |
Location: | Zhengzhou, Henan, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Model No.: | electrical wire |
---|---|
Means of Transport: | Ocean, Air, Land |
Application: | Others |
Type: | Low Voltage |
Insulation Material: | PVC |
Jacket: | PVC |
Conductor Material: | Copper |
Brand Name: | Aobest |
Color: | Various |
Type: | Electric wire |
Voltage: | Low Voltage |
Size: | 1.5mm2/2.5mm2/4mm2/6mm2/10mm2/16mm2 |
Production Capacity: | 5000 kilometers |
Packing: | 100 meters per coil |
Delivery Date: | 10 days for one container |
Superior PVC insulated electrical wire 450/750V home wire
1.Range of Application
The PVC insulated power cable and fire resistant cable are suitable for fixed laying in power transmission and distribution lines with A.C.50HZ and voltage rating of up to or including 6KV.
2. Model and Name
Model | Name |
BV | Copper Core PVC Insulation Wire |
BLV | Aluminum Core PVC Insulation Wire |
BVR | Copper Core PVC Insulation Flexible Wire |
BVV | Copper Core PVC Insulation PVC Sheath Round Wire |
BVVB | Copper Core PVC Insulation PVC Sheath Flat Wire |
BLVVB | Aluminum Core PVC Insulation PVC Sheath Flat Wire |
BV-90 | Copper Core Heat-resistance 105oC PVC Insulation |
3.Specification,Size and Technical Data
Nominal Section(mm2) | No/Dia.of Core(mm) | Max, O.D (mm) | Reference Weight(kg/km) | Conductor Resistance at 20oC≤(Ω/km) | ||
Copper | Aluminum | Aluminum | Copper | |||
1.0(A) | 1/1.3 | 2.8 | 13.90 | 18.10 | ||
1.0(B) | 7/0.43 | 3.0 | 15.0 | 18.10 | ||
1.5(A) | 1/1.38 | 3.3 | 20.3 | 12.1 | ||
1.5(B) | 7/0.52 | 3.5 | 21.6 | 12.1 | ||
2.5(A) | 1/1.78 | 3.9 | 31.6 | 17 | 11.8 | 7.41 |
2.5(B) | 7/0.68 | 4.2 | 34.8 | 7.41 | ||
4(A) | 1/2.55 | 4.4 | 47.1 | 22 | 7.39 | 4.61 |
4(B) | 7/0.85 | 4.8 | 50.3 | |||
6(A) | 7/0.85 | 4.8 | 50.3 | 29 | 4.91 | 3.08 |
6(B) | 7/1.04 | 5.4 | 71.2 | 3.08 | ||
10 | 7/1.35 | 7.0 | 119 | 62 | 3.08 | 1.83 |
16 | 7/1.70 | 8.0 | 179 | 78 | 1.91 | 1.15 |
25 | 27/2.04 | 10.0 | 281 | 118 | 1.20 | 0.727 |
35 | 27/2.52 | 11.5 | 381 | 156 | 0.868 | 0.524 |
50 | 19/1.78 | 13.0 | 521 | 215 | 0.641 | 0.387 |
70 | 19/2.14 | 15.0 | 734 | 282 | 0.443 | 0.268 |
95 | 19/2.52 | 17.5 | 962 | 385 | 0.320 | 0.193 |
120 | 37/2.03 | 19.0 | 1180 | 431 | 0.253 | 0.153 |
150 | 37/2.25 | 21.0 | 1470 | 539 | 0.206 | 0.124 |
4 .Product performance
(1)The long-time permissible operation temperture of conductor shall not be higher than 70.
(2)Conductor maximum short circuit (not more than 5 seconds)temperature shall not be higher than 160.
(3)The cable is not limited by drop in level when being laid,and the ambient temperature shall not be lower than 0.
(4)Perfect chemical stability,resistant against acids,alkalis,grease and organic solvents,and flame.
(5)Light weight,perfect bending properties,installed and maintained easily and conveniently.
Voltage rating0.6/1KV 3.6/6KV
Conductors copper or aluminum.
Number of cable cores:one core(Single core),two cores(Double cores),three cores,four cores(Four equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),five cores(Five equal-section-area cores or three equal-section-area cores and two smaller section area neutral cores).We provide armoured type and non-armored type for the cables above.