Overhead Conductor AAC AAAC ACSR Conductor

1.0~180.0 USD
Min. Order: 1 Kilometer
Trade Term: FOB
Payment Terms: L/C, T/T, WU
Supply Ability: 3000 kilometers
Place of Origin: Henan

Company Profile

Location: Zhengzhou, Henan, China (Mainland)
Business Type: Manufacturer, Trading Company

Product Detail

Model No.: AAC,AAAC ACSR
Means of Transport: Ocean, Air, Land
Application: Overhead
Type: Low Voltage
Insulation Material: Others
Jacket: Others
Conductor Material: Aluminum
Brand Name: Aobest
Type: Bare Conductor
Conductor Material: Aluminum
Voltage: Low Voltage
Standard: IEC61089,ASTM B231,BS215,CSA C49,DIN48204
Production Capacity: 3000 kilometers
Packing: wooden drum or as your request
Delivery Date: 10 days for one container
Show

Product Description

Overhead Conductor AAC AAAC ACSR Conductor

1. Standard: According to IEC61089, also can do by standard of ASTM B232,BS315,DIN48204 or other standards as request.
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
2. Construction:
ACSR is composed by concentric-lay-stranded galvanized steel wires and aluminium wires.
3. Characters:
a.Under the same weight,ACSR is with lower cost than Copper conductor
b.In order to foster the prevention of corrosion,the non-oxidizing grease can be fully or partially applied to ACSR
c.ACSR offers optimal strength for line design.Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
4. Application:
Overhead electric power transmission and distribution lines with various grade voltages. It is very suitable for laying across basins, rivers and valleys where special geographical terrain exist
5. Advantages:
a. Excellent electric and mechanical characteristics.
b. Good conductivity, Resistance chemical corrosion and heat-ageing,environment stress.
c. Unit volume light, Simple in structure.
d. Convenient to use,especially for laying across rivers and valleys where special geographical terrain exist.
6.Service Performance
(1).The permissible long-time operating temperature for aerial conductor is 70oC.
(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
The data sheets below show the most common standards,British standard and IEC standard,IEC Sizes IEC 61089
Code Number
Stranding&wire diameter
Approx Overall diameter
Nominal
area
Approx.
Weight
Breaking Load
DC Resistance at 20
mm
mm
mm2
Kg/km
KN
Ohm/km
16
25
40
63
100
125
160
200
250
315
400
450
500
560
630
710
800
900
1000
1120
1250
7/1.83
7/2.29
7/2.89
7/3.63
19/2.78
19/3.10
19/3.51
19/3.93
19/4.39
37/3.53
37/3.98
37/4.22
37/4.45
61/3.67
61/3.89
61/4.13
61/4.38
91/3.81
91/4.01
91/4.25
91/4.49
5.49
6.86
8.68
10.9
13.9
15.5
17.6
19.6
22.0
24.7
27.9
29.6
31.2
33.0
35.0
37.2
39.5
41.8
44.1
46.7
49.4
18.4
28.8
46.0
72.5
115
144
184
230
288
363
460
518
575
645
725
817
921
1036
1151
1289
1439
50.4
78.7
125.9
198.3
316.3
395.4
506.1
632.7
790.8
998.9
1268.4
1426.9
1585.5
1778.4
2000.7
2254.8
2540.6
2861.1
3179.0
3560.5
3973.7
5.43
8.49
13.58
21.39
33.95
42.44
54.32
67.91
84.88
106.95
135.81
152.79
169.76
190.14
213.90
241.07
271.62
305.58
339.53
380.27
424.41
1.7896
1.1453
0.7158
0.4545
0.2877
0.2302
0.1798
0.1439
0.1151
0.0916
0.0721
0.0641
0.0577
0.0516
0.0458
0.0407
0.0361
0.0321
0.0289
0.0258
0.0231
BS EN 50182:2001
Code Name
Stranding&wire diameter
Approx Overall diameter
Total area
Weight
Breaking Load
DC Resistance at 20
Current Rating
mm
mm
mm2
Kg/km
KN
Ohm/km
A
Box
Acacia
Almond
Cedar
Deodar
Fir
Hazel
Pine
Holly
Willow
Oak
Mulbery
Ash
Elm
Poplar
Sycamore
Upas
Yew
Totara
Rubus
Sorbus
Araucaria
Redwood
7/1.85
7/2.08
7/2.34
7/2.54
7/2.77
7/2.95
7/3.30
7/3.61
7/3.91
7/4.04
7/4.65
19/3.18
19/3.48
19/3.76
37/2.87
37/3.23
37/3.53
37/4.06
37/4.14
61/3.50
61/3.71
61/4.14
61/4.56
5.55
6.24
7.02
7.62
8.31
8.85
9.90
10.80
11.70
12.10
13.95
15.90
17.40
18.80
20.10
22.60
24.70
28.40
29.42
31.50
33.40
37.30
41.00
18.8
23.9
30.1
35.5
42.2
47.8
59.9
71.6
84.1
89.7
118.9
150.9
180.7
211.0
239.4
303.2
362.1
479.0
498.1
586.9
659.4
821.1
996.2
51.4
64.9
82.2
96.8
115.2
130.6
163.4
195.6
229.5
245.0
324.5
414.3
496.1
579.2
659.4
835.2
997.5
1319.6
1372.1
1622.0
1822.5
2269.5
2753.2
5.55
7.02
8.88
10.46
12.44
14.11
17.66
21.14
24.79
26.47
35.07
44.52
53.31
62.24
70.61
89.40
106.82
141.31
146.93
173.13
194.53
242.24
293.88
1.7480
1.3828
1.0926
0.9273
0.7797
0.6875
0.5494
0.4591
0.3913
0.3665
0.2767
0.2192
0.1830
0.1568
0.1387
0.1095
0.0917
0.0693
0.0666
0.0567
0.0505
0.0406
0.0334
93
110
128
132
148
161
184
204
222
233
272
319
354
385
414
487
527
629
640
716
760
842
920

Overhead Conductor AAC AAAC ACSR Conductor

Post Buying Request