600/1000V YFGY YRGY NYFGBY NYRGBY PVC insulated steel wire armored power cable

1.0~66.0 USD
Min. Order: 500 Meter
Trade Term: FOB
Payment Terms: L/C, T/T, WU
Supply Ability: 50000m/week
Place of Origin: Henan

Company Profile

Location: Zhengzhou, Henan, China (Mainland)
Business Type: Manufacturer, Trading Company

Product Detail

Model No.: YFGY YRGY
Means of Transport: Ocean, Air, Land
Application: Construction
Type: Low Voltage
Insulation Material: PVC
Jacket: PVC
Conductor Material: Copper
Brand Name: Aobest
Color: red/black/blue/yellow/green
Type: PVC power cable
Core: 1,2,3,4,5,6
conductor: Aluminum/Copper/CCA
voltage: 600/1000V
Production Capacity: 50000m/week
Packing: standard wooden drum
Delivery Date: 15days for one container
Show

Product Description

600/1000V YFGY YRGY NYFGBY NYRGBY PVC insulated steel wire armored power cable


Cross Section: 1.5-800mm2
No. Of cores: 1-6
Standard: IEC 60502-1
Certificate: ISO9001 CCC CE SGS

600/1000V YFGY YRGY NYFGBY NYRGBY PVC insulated steel wire armored power cable application

Aobest 600/1000V YFGY YRGY NYFGBY NYRGBY PVC insulated steel wire armored power cable & fire resistant cable are suitable for fixed laying in power transmission and distribution lines with AC 50Hz ,voltage rating up to 6 KV.

600/1000V YFGY YRGY NYFGBY NYRGBY PVC insulated steel wire armored power cable performance characteristics:

1. Rated voltage of the 600/1000V YFGY YRGY NYFGBY NYRGBY PVC insulated steel wire armored power cable: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV),8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV and 0.6/1kV.
2. The highest allowed operating temperature of conductor for long-term working is 90oC. Inshort-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degree.
3. D. C. Resistance of the conductor complies with the stipulations of international standar.
4.The environment temperature should be no lower than zero degree when lay.Otherwise it should be preheated.
5. The cable is laid without horizontaldrop limit. The Min. Bending radius of cables should be no smaller than 12 timesof cable outer diameter.
6. Working Frequency Voltage Test:
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable withUo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and26 kV: 2.5Uo/30min without puncture.

Related Aobest PVC insulate power cable types:
Type
Discription
Rated Voltage(KV)
Core Quantity
Nominal Cross-sectional   Area (mm²)
Cu
Al
VV
       VLV
VV: Copper conductor PVC insulated and PVC sheathed powercables.   
   VLV: Aluminum conductor PVC insulated and PVC sheathed powercables.
0.6/1KV
1
1.5~1200
2.5~1200
2
1.5~300
2.5~300
3
1.5~300
2.5~300
4
1.5~300
2.5~300
5
1.5~300
2.5~300
3+1
1.5~300
2.5~300
3+2
1.5~300
2.5~300
4+1
1.5~300
2.5~300
VV22
     VLV22
VV22: Copper conductor PVC insulated and PVC sheathedsteel tap armoured power cables.               
VV22: Aluminum conductor PVC insulated and PVCsheathed steel tap armoured power cables.
0.6/1KV
1
10~500
10~500
2
1.5~300
2.5~300
3
1.5~300
2.5~300
4
1.5~300
2.5~300
5
1.5~300
2.5~300
3+1
1.5~300
2.5~300
3+2
1.5~300
2.5~300
4+1
1.5~300
2.5~300
VV32
VLV32
VV32: Copper conductor PVC insulated and PVC sheathedsteel wire armoured power cables.               
VLV32: Aluminium conductor PVC insulated and PVCsheathed steel wire armoured power cables.
0.6/1KV
1
50~500
50~500
2
35~300
50~185
3
25~300
35~300
4
25~300
35~300
5
25~240
35~240
3+1
25~300
35~300
3+2
25~300
35~300
4+1
25~240
35~240


Many other PVC/XLPE power cable,rubber cable,ABC cable,bare AAC/AAAC/ACSR conductor,control cable can be produced. More info needed, pls contact me freely.