user login

CE, EN, UL Approved 2-Wire Conventional Heat Detector

5.0~12.0 USD
Min. Order: 1000 Piece/Pieces
Trade Term: FOB
Payment Terms: L/C, T/T, WU
Supply Ability: 5000000PCS/YEAR
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: LED Remote Indicator Sensitive Conventional Flame Detector, 9VDC Block SND-500-S Smoke Alarm, 2-wire Intelligent Addressable Smoke Detector, 2-Wire 60 UA Photoelectronic Smoke Detector, 2 Wire LED Remote Indicator Conventional Heat Detector

Product Detail

Model No.: HNC-310-H2
Means of Transport: Ocean, Air, Land
Usage: Fire
Brand Name: NUMENS
DETECTOR CLASS: Fixed and Rate of Rise Temperature
SUPPLY WIRING: 2 -WIRE Polarity Insensitive
DESIGN STANDARD: EN 54-5 and UL 521
APPROVAL: CE and UL
SUPPLY VOLTAGE: 10.8V to 33V DC
QUIESCENT CURRENT: 40μA @24V
ALARM CURRENT: 50mA@24V
TEMPERATURE RANGE: -20℃ to +60℃
HUMIDITY: 0% to 95% RH No Condensation
SENSITIVITY: 57℃,AIR
Production Capacity: 5000000PCS/YEAR
Packing: 1pc/box, 100pcs/ctn, Or package as customer's request
Delivery Date: 20 to 35days
Show

Product Description

 CE, EN, UL Approved 2-Wire ConventionalHeat Detector

Model HNC-310-H2 fixed and rate of rise heat detectors provide fast and reliable
response for heat 57°C(135oF) detection.
The detector may work with most modern fire alarm control panels, and can be installed with
the series 65 of Apollo together,also the series NB 338 of WIZMART and the FEOE 2000 of ZETA etc.

CE, EN, UL Approved 2-Wire Conventional Heat Detector


Features:
1) 2-Wire operation
2) Wide operating voltage
3) Advanced electronic technology
4) Proven detection performance
5) UL \BSI and CE approval
CE, EN, UL Approved 2-Wire Conventional Heat Detector
Specification:
MODEL
HNC-310-H2
DETECTOR CLASS
Fixed and Rate of Rise Temperature
SUPPLY WIRING
2 – WIRE
DESIGN STANDARD
EN 54-5 and UL521
APPROVAL
CE and UL
SUPPLYVOLTAGE
10.8V to 33V DC
QUIESCENT CURRENT
40μA @24V
ALARM CURRENT
50mA@24V
TEMPERATURE RANGE
-20°C to +60°C
HUMIDITY
0% to 95% RH No Condensation
SENSITIVITY
57°C, AIR
IP RATING
IP 43
START-UP TIME
10 Seconds
DIMENSIONS (dia. x height)
102 x 56mm (with Base)
WEIGHTS
120g (with Base)


Model:
HNC-310-H2 2-Wire Fixed and Rate of Rise Heat Detector
HNC-310-HL 2-Wire Fixed and Rate of Rise Heat Detector with Remote Indicator
HNC-310-HR 4-Wire Fixed and Rate of Rise Heat Detector with Relay Output Function
CE, EN, UL Approved 2-Wire Conventional Heat DetectorCE, EN, UL Approved 2-Wire Conventional Heat Detector
CE, EN, UL Approved 2-Wire Conventional Heat Detector
CE, EN, UL Approved 2-Wire Conventional Heat Detector
Post Buying Request