Multiple loop Fire alarm control station

50.0~100.0 USD
Min. Order: 50 PCS
Trade Term: FOB
Payment Terms: L/C, T/T
Supply Ability: 10000 Pieces per month
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: LED Remote Indicator Sensitive Conventional Flame Detector, 9VDC Block SND-500-S Smoke Alarm, 2-wire Intelligent Addressable Smoke Detector, 2-Wire 60 UA Photoelectronic Smoke Detector, 2 Wire LED Remote Indicator Conventional Heat Detector

Product Detail

Means of Transport: Ocean, Air
Brand Name: Numens
POWER SUPPLY: AC 85 ~ 260V
Number of Loop: 8
Zone current (duty mode): 5 mA
Zone current (alarm mode): 20 ~ 60mA
HUMIDITY: 0% to 95% RH No Condensation
Max. Cable Resistance: 500 Ohms
DIMENSIONS: 358(W)*273(H)*90(D)mm
Weigh: 5KG
Number of zone: 2
Max. Cable Capacitance: 0.47uF
Production Capacity: 10000 Pieces per month
Packing: Box packing; 6PCS/CTN
Delivery Date: 20-30DAYS
Show

Product Description


Product name: 8 Zone conventional fire control panel
8 Zone conventional fire control panel
8 Zone conventional fire control panel


Series PNC-1000 fire panel is an up-to-date, highly reliable, multifunctional and versatile unit. It is designed to receive signals from manual call points and automatic fire detectors, releasing sound and light indication.
The fire control panel provides options for two conventional sounder circuits, three class change and alert inputs, two fire and fault outputs, a fault out and a reset output. A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities, Comprehensive test and fault finding facilities are also provided on the intuitive user-friendly interface.

. Features
• Two, four and eight zone non-expandable control panels.
• Up to 32 conventional smoke and/or heat detectors per zone.
• • • Delay timer programmable on/off per zone.
• Zone coincidence programmable for adjacent zones.
• Two Access Levels.
• One man test.
• Supervised auxiliary 24 volt output.
• 2 supervised/ monitored sounder circuits.
• 2 programmable inputs for Class change, remote silence, remote reset etc.
• 2 Relay outputs fire and fault.
• Power supply 1,5A at 28Vdc.
• Fully EN54 part 2 and 4 compliant.
• Repeater output.



1) Programmable non-latching zones.
2) Available with 8 Zone Circuits
3) Up to 32 Conventional Devices Can Be Connected to Each Zone
4) Class change and alert inputs
5) Day / Night Mode, and Reset
6) 2 Supervised/Monitored Sounder Circuits
7)Active End of Line monitoring.
8)Command for Silencing Signaling Devices
9)Multiplexed output for Leds and additional relay outputs per zone.
10)Fully Complies with The Requirements of EN 54 Part 2 and 4
Specifications
Model
PNC-1000-8Z
Number of Loop
8
Main Power Supply
AC 85 ~ 260V
Backup Batteries
2×12VDC (4.5 AH)
Zone Current (Duty Mode)
5mA
Zone Current (Alarm Mode)
20 ~ 60 mA
Max. Cable Resistance
500Ohms
Max. Cable Capacitance
0.47µF
Range of Temperature
0 to +50℃
Max. Humidity
30% to 95% RH No Condensation
Dimensions
358(W)*273(H)*90(D)mm
Weigh
5Kg (Include battery)

8 Zone conventional fire control panel
Post Buying Request