user login

4 wire conventional relay output smoke and heat combined detector

1.0~7.0 USD
Min. Order: 1000 PCS
Payment Terms: L/C, T/T
Supply Ability: 100000 Pieces per month
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: LED Remote Indicator Sensitive Conventional Flame Detector, 9VDC Block SND-500-S Smoke Alarm, 2-wire Intelligent Addressable Smoke Detector, 2-Wire 60 UA Photoelectronic Smoke Detector, 2 Wire LED Remote Indicator Conventional Heat Detector

Product Detail

Model No.: SNC-100-CR
Means of Transport: Ocean, Air
Usage: Smoke
Brand Name: Numens
Wiring:: 4 wire
Power supply:: 12 to 48 V DC
Quiescent current:: 60 uA
Alarm current: 50 mA
Temperature:: -10℃ to +55℃
DETECTOR CLASS: Photoelectronic smoke and heat
APPROVAL: CE
RELAY: Relay output
IP RATEING: IP43
ALARM TEMPERATURE: 57℃
Production Capacity: 100000 Pieces per month
Packing: 1PC INNER BOX; 100PCS/CTN
Delivery Date: 30DAYS
Show

Product Description


Product name:
4 wire conventional relay output smoke and heat combined detector
Model No: SNC-100-CR

4 wire conventional relay output smoke and heat combined detector
Base details:
4 wire conventional relay output smoke and heat combined detector

Description:
SNC-100-CR detectors which provide fast and reliable response for smoke and heat 57℃(135oF) detection. While the smoke and heat detection circuits operate independently, their outputs being "OR' connected, and provide the fire detection performance by acting as a smoke sensor and/or a 57℃ (135oF) heat detector at the same location.
The SNC-100-CR detectors have a integral relay, connected between the "6" terminal and the "3" terminal, which provides one set of volt-free changeover (form A) contacts that change state when the detector signals an alarm.
The detector will work with most modern fire alarm control panels\security systems, and meet s the requirements of UL 521&268 and EN 54-5/7.
Feature:
1) 4-Wire operation
2) Optical & thermal detection
3) Built-in alarm relay
4) Wide operating voltage
5) Advanced electronic technology
6) Proven detection performance
7) Designed to meet approvals worldwide (e.g. UL VDS CE)
Specification:
MODEL
SNC-100-CR
DETECTOR CLASS
Optical Smoke
SUPPLY WIRING
4 – WIRE
DESIGN STANDARD
EN 54-7 and UL 268
APPROVAL
CE
SUPPLY VOLTAGE
12 to 48VDC;   
QUIESCENT CURRENT
60μA @12V
ALARM CURRENT
35mA@12V
TEMPERATURE RANGE
-10℃ to +55℃
HUMIDITY
0% to 95% RH No Condensation
SENSITIVITY
UL:2.3%FT; EN 54:0.15dB/m
IP RATING
IP 43
START-UP TIME
10 Seconds
DIMENSIONS (dia. x height)
99 x 62mm (with Base)
WEIGHTS
130g

Schematic wiring diagram:
4 wire conventional relay output smoke and heat combined detector4 wire conventional relay output smoke and heat combined detector
Post Buying Request