user login

4 wire conventional relay output smoke detector

1.0~6.0 USD
Min. Order: 1000 PCS
Payment Terms: L/C, T/T
Supply Ability: 100000 Pieces per month
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: LED Remote Indicator Sensitive Conventional Flame Detector, 9VDC Block SND-500-S Smoke Alarm, 2-wire Intelligent Addressable Smoke Detector, 2-Wire 60 UA Photoelectronic Smoke Detector, 2 Wire LED Remote Indicator Conventional Heat Detector

Product Detail

Model No.: SNC-100-SR
Means of Transport: Ocean, Air
Usage: Smoke
Brand Name: Numens
Wiring:: 4 wire
Power supply:: 12 to 48 V DC
Quiescent current:: 60 uA
Alarm current: 50 mA
Temperature:: -10℃ to +55℃
DETECTOR CLASS: Photoelectronic
APPROVAL: CE
RELAY FUNCTION: Relay output
QUIESCENT CURRENT: 60μA @24V
ALARM CURRENT: 50mA@24V
Production Capacity: 100000 Pieces per month
Packing: INNER BOX; 100PCS/CTN
Delivery Date: 30DAYS
Show

Product Description

Product name:
4 wire conventional relay output smoke detector
Model No: SNC-100-SR
4 wire conventional relay output smoke detector

Base details:
4 wire conventional relay output smoke detector
Model SNC-100-SR smoke detector uses a specialized smoke chamber design, which could sense the presence of smoke particles produced by fast combustion or slow smoldering fire.
The SNC-100-SR detector has a integral relay with form A (NO), connected between the "6" terminal and the "3" terminal, its provide one set of volt-free changeover (form A) contacts change state when the detector signals an alarm.
The detector will work with most modern fire alarm control panels\security systems, and meets the requirements of UL 268 and EN 54-7.
Features:
1) 4-Wire Operation
2) Built-in Alarm Relay
3) Wide Operating Voltage
4) Advanced Electronic Technology
5) Proven Detection Performance
6) Designed to Meet Approvals Worldwide
Specification:
MODEL
SNC-100-SR
DETECTOR CLASS
Optical Smoke
SUPPLY WIRING
4 – WIRE
DESIGN STANDARD
EN 54-7 and UL 268
APPROVAL
CE;
SUPPLY VOLTAGE
12 to 48V DC
QUIESCENT CURRENT
60μA @24V
ALARM CURRENT
50mA@24V
TEMPERATURE RANGE
-10℃ to +55℃
HUMIDITY
0% to 95% RH No Condensation
SENSITIVITY
UL:2.3%FT; EN 54:0.15dB/m
IP RATING
IP 43
START-UP TIME
10 Seconds
DIMENSIONS (dia. x height)
99 x 46mm (with Base)
WEIGHTS
130g
NOTE: * TEST FUNCTION WITH MAGNETIC

Schematic wiring diagram:
4 wire conventional relay output smoke detector
4 wire conventional relay output smoke detector
Post Buying Request