user login

Remote LED indicator output 2-wire conventional heat detector

1.0~5.0 USD
Min. Order: 1000 PCS
Payment Terms: L/C, T/T
Supply Ability: 5000000 Pieces per Year
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: LED Remote Indicator Sensitive Conventional Flame Detector, 9VDC Block SND-500-S Smoke Alarm, 2-wire Intelligent Addressable Smoke Detector, 2-Wire 60 UA Photoelectronic Smoke Detector, 2 Wire LED Remote Indicator Conventional Heat Detector

Product Detail

Model No.: HNC-110-HL
Means of Transport: Ocean, Air
Usage: Fire
Brand Name: Numens
Wiring:: 2 wire
Power supply:: 10.8 to 33 V DC
Quiescent current:: 40 uA
Alarm current: 50 mA
Temperature:: -10℃ to +55℃
DETECTOR CLASS: fixed and rate of rise temperature
APPROVAL: CE
HEAT ALARM: 57℃(135F)
REMOTE INDICATOR: Remote LED output function
ALARM CURRENT: 50mA@24V
Production Capacity: 5000000 Pieces per Year
Packing: 1PC INNER BOX; 100PCS/CTN
Delivery Date: 30DAYS
Show

Product Description

Product name:
Remote LED indicator output 2-wire conventional heat detector
Model No: HNC-110-HL
Remote LED indicator output 2-wire conventional heat detector
HNC-110-HL heat detectors provide an effective solution and fast response in case intense fire under rapid temperature rise situation, and the series range is classified according to EN54-5 as fixed and rate of rise temperature detectors.
HNC-110-HL heat detectors incorporate well proven sensing technologies, together with advances in materials and electronics technology, and represent the pinnacle of fire detector performance and reliability.
The detector will work with most modern fire alarm control panels, and meets the requirements of UL 521 and EN 54-5.


1) Fixed 57℃(135F) and rate of rise of temperature alarm.
2) Low standby current
3) anti-EMI and anti-RFI
4) LED visible in 360 degree direction.
5) Designed to meet approvals worldwide (e.g. UL LPCB CE)
6) Sensor base: optional installation mode.
Specification:
MODEL
HNC-110-HL
DETECTOR CLASS
Fixed and Rate of Rise Temperature
SUPPLY WIRING
2 – WIRE
DESIGN STANDARD
EN 54-5 and UL 521
APPROVAL
CE
SUPPLY VOLTAGE
10.8 to 33V DC
QUIESCENT CURRENT
40μA @24V
ALARM CURRENT
50mA@24V
TEMPERATURE RANGE
-10℃ to +55℃
HUMIDITY
0% to 95% RH No Condensation
SENSITIVITY
57℃,A2
IP RATING
IP 43
START-UP TIME
10 Seconds
DIMENSIONS (dia. x height)
99 x 46mm (with Base)
WEIGHTS
120g (with Base)

Base details:
Remote LED indicator output 2-wire conventional heat detector

Schematic Wiring Diagram:

Remote LED indicator output 2-wire conventional heat detector

Remote LED indicator output 2-wire conventional heat detector
Post Buying Request