Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB,CFR,CIF,DDP,DAP,CIP,CPT,FCA,EXW |
Payment Terms: | L/C, T/T |
Supply Ability: | 10 sets per month |
Place of Origin: | Shaanxi |
Location: | Xi'an, Shaanxi, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company, Agent, Distributor/Wholesaler, Service, Association, Other |
Main Products: | 8-1/2 Spiral Blade Stabilizer AISI 4145H MOD, AISI 4145H MOD Stabilizer For Well Drilling, 4 1/2 RTTS Safety Joint, 5 RTTS Safety Joint, RTTS PACKER |
Model No.: | API |
---|---|
Means of Transport: | Ocean, Air, Land |
Type: | Others |
Certification: | Others |
Brand Name: | KINGWELL |
Model number: | FKQ 1280-7 |
Country of Origin: | China |
Pressure range: | 0-14MPa |
Warranty: | 1 year |
Usage: | BOP control |
Condition: | New |
Packaging: | Standard export package |
Certification: | API |
Production Capacity: | 10 sets per month |
Packing: | Standard export package |
Delivery Date: | 90 days |
Functions of A Blowout Preventer Control System:
Confine well fluid to the wellbore;
Provide means to add fluid to the wellbore;
Allow controlled volumes of fluid to be withdrawn from the wellbore.
Additionally, and in performing those primary functions, blowout preventer systems are used to:
Regulate and monitor wellbore pressure;
Center and hang off the drill string in the wellbore;
Shut in the well (e.g. seal the void, annulus, between drillpipe and casing);
Prevent the flow of formation fluid, influx, from the reservoir into the wellbore
Seal the wellhead (close off the wellbore);
Sever the casing or drill pipe (in case of emergencies).
Components of the Blowout Preventer Control System:
Item | Descriptions | Unit | Qty. |
I | BOP Control Accumulator Unit (Control System for Surface Mounted BOP Stacks, pressure range 0-14MPa) Country of Origin: China Brand Name: Model number: FKQ 1280-7
| Lot | 1 |
(A) | Specifications for BOP Control Accumulator Unit | ||
(a) Quantity of preventers operated | 7 | ||
(b) System working pressure | MPa | 21 | |
(c) Total volume of accumulators | Liters | 16 | |
(d) Effective reservoir capacity | Liters | 1600 | |
(e) Regulating range of pressure | MPa | 0-14 | |
(f) Air pressure | MPa | 0.65-0.8 | |
(g) Nitrogen pressure charge in accumulator | MPa | 7±0.7 | |
Control manifold header consists of 4 way valves, pressure reducing and regulating valve, pressure relief valve for accumulator recommended pressure gauges with gurad, bleeder valve, and recommended other valves and accessories etc be mounted on unit. | |||
(B) | Control panel | ||
Remote control panel | Set | 1 | |
Driller panel | Set | 1 | |
Protection hose | Set | 1 | |
Alarm device | Set | 1 | |
Air cable | Set | 1 | |
Tools& sealing box | Set | 1 | |
(C) | Triplex single acting plunger pump | Set | 2 |
(a) Model: QB 21/80 | |||
(b) Nominal pressure | MPa | 21 | |
(c) Nominal displacement | ml/rev | 80 | |
(d) Plunger diameter | mm | 25 | |
(e) Plunger travel | mm | 56 | |
(D) | Motor for triplex single acting plunger pump | sets | 2 |
(a) Motor type: YB2-180M-4W | |||
(b) Protection type: Exd 3 IIBT-4 | |||
(c) Power | Kw | 18.5 | |
(d) Speed | RPM | 1470 | |
(e) Voltages | V | 380/660 | |
(f) Ampere | A | 36.5/21.1 | |
(g) Phase | phase | 3 | |
(h) Frequency | Hz | 50 | |
(E) | Air pump | sets | 2 |
(a) Model: QYB40-165L | |||
(b) Air pressure | MPa | 0.53-0.8 | |
(c) Hydraulic to air pressure ratio | 50:1 | ||
(F) | General | ||
(a) Nitrogen pressure charging hose assy (with pressure gauge 0-5000psi, hose pipe L-5Meter,etc) | set | 1 | |
(b) 1"Dia high pressure hose pipe (working pressure 3000psi, test pressure 6000psi) | Meter | L-5 | |
(c) Both ends connected with 1"Dia high pressure union Male and Female (working pressure 3000psi, test pressure 6000psi) | sets | 10 | |
(d) 1"Dia high pressure hose pipe, L-12Meter (working pressure 3000psi, test pressure 6000psi) | sets | 20 | |
(e) Both ends connected with 1"Dia high pressure union Male and Female (working pressure 3000psi, test pressure 6000psi) | sets | 20 | |
(G) | Spares for BOP control accumulator unit | ||
(a) 1"HP Valve (5000psi) | sets | 2 | |
(b) 1"Check valve(5000psi) | sets | 2 | |
(c) 1" HP 4 way Bypass valve (5000psi) | sets | 2 | |
(d) Bladder for Cylinder | sets | 8 | |
(e)Pressure gauge (0-5000psi)(1"-connection) | sets | 2 | |
(f) Pressure reducing and regulating valve | sets | 2 | |
(g) Pressure relief valve | sets | 2 | |
(h) 7/052 PVC Single wire, double insulation PVC wire-(length) | meter | 300 | |
(H) | Spare for triplex pump Ex BOP control accumulator unit | ||
a) 1"Plunger | sets | 12 | |
(b) 1"Plunger packing | sets | 36 | |
(c) suction valve seat | Nos | 12 | |
(d) suction valve assy | Nos | 12 | |
(e) Discharge valve seat | Nos | 12 | |
(f) Discharge valve assy | Nos | 12 | |
(I) | Literature | ||
Required to be supplied each 5 complete sets of the following literatures in English edition, both hard copies and soft copies to this office before or along with the shipment. Maintenance/workshop manuals Instruction/operation manuals Parts catalogues |
Company Introduction
XI'AN KINGWELL OILFIELD MACHINERY Co., Ltd. (KINGWELL) is a highly reputable supplier for oilfield equipment and services to Oil & Gas industries and provides complete solutions.
With over 10 years developing, we were developed from the beginning drilling service to manufacture factory who produce OCTG, drilling tools, DST tools and Solid control products.
KINGWELL have experienced team, stronger enough to meet any challenge, we do believe honest is the base of business and cooperation; our aim is to build solid relationship with any part of honest. kingwell can provide highly efficient services to its clients resulting in accurate and timely deliveries at the best prices. Our products have been exported to Europe, American and Middle East.