user login

Universal Laptop Battery Tester

270.0~290.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: Paypal, T/T, WU
Supply Ability: 10000 sets/year
Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Power Bank, Charger, Laptop Battery Tester

Product Detail

Model No.: RFNT3
Means of Transport: Ocean, Air
Production Capacity: 10000 sets/year
Packing: 1 set/box
Delivery Date: 2-5 days
Show

Product Description

 
Basic Parameters
Dimensions: 201 x 99 x 35 mm
Weight: 333g
Adapter    Input: AC 100 ~ 240 V   Output: DC 24V 2.65A
Display mode
Segment LCD with white backlight + LED in red and green
Discharging mode
Constant current discharge for double loaders, inner loader & external loader
Charging mode
Constant current and constant voltages are the main mode. Active charge and pre-charge are available according to different battery voltage.
Active charge:
Tester may not recognize 0V-battery. Users should press the charge key to start up the active charge function. Being activated and going to normal charging status, when the battery establishes communication with the tester.
Pre-charge:
Tester goes into pre-charge status when voltage of single cell < 3000mV.
Constant current:
Tester goes into fast charge status when voltage of single cell > 3000mA & < 4200mA. Fast charge current relates to the battery nominal capacity.
At the end of charge:
The current intensity begins to decrease when tester goes into constant voltage charge status. It stops charging when the capacity reaches 100% and the current intensity less than 1A or the current intensity reduce to the end charge current.
Function Introduction
Charge
Active, pre-charge, constant current and constant voltages are the stages of charging mode. The initial charging mode depends on the battery voltage, so active and pre-charge don't happen to every batteries. For charging mode and current, please refer to the paragraphs of charging mode and charging current on page 2 & 3.
Tester will stop charging if one of the conditions below was met.
1) Remaining capacity is more than 99% & current intensity = 0
2) Remaining capacity = full charge capacity
3) Current intensity reduce to end charge current when constant voltage charge
4) Remaining capacity reach up the set value
Discharge
Constant current discharge for double loads
Inner load: 0 ~ 1000mA, adjustable continuously via Battery Manager
External load: 0mA, 500mA, 1000mA, 1500mA, 2000mA, five gears with dip switches offered
Tester will stop discharging if one of the conditions below is met.
1) Remaining capacity is less than setted value
2) Voltage is less than setted value
3) Current intensity reduce to zero
Remarks:
Many batteries can not measure exact current intensity, which cause an else current value appears after you set a value. However, the actual discharging current is the same with your set value.
Test
Testing time is 12 seconds and the purpose is to check both the charging and discharging performances. After finishing test, LED flickers with green color and LCD reports the test result.
Normal:              Test           OK            Shown on LCD
Abnormal:            Test           NG            Shown on LCD
Possible causes and solutions for the abnormal:
1) Cause: battery voltage is too low to discharge
   Solution: try to charge the battery to raise voltage
2) Cause: remaining capacity is too full to charge any more
   Solution: try to discharge the battery to reduce the remaining capacity
3) Bad contact of battery connecting wires
4) Damaged battery
5) Tester trouble
Capacity Correction
The battery capacity value in the battery management chip will different from the actual capacity after a battery goes through many recycling cycles. It will affect the use of the battery when the difference reaches a certain degree. Capacity correction is to deep discharge a battery and then fully charge, which will correct the capacity value in the battery management chip.
Remarks:
Discharging current can be set via Battery Manager. Deep discharge will cause a battery losing communication with tester, so battery dropping phenomenon may happen in the discharging process if the end capacity and voltage are set too low. In such a case, active charge will make the battery work again.
50% Capacity
CD50%: charge firstly, and then discharge to 50% capacity
DC50%: discharge firstly, and then charge to 50% capacity
Online Functions
Tester can be connected with master machine via a USB port. Users can monitor, control and set parameters via Battery Manager software in the master machine.
Monitoring
Battery information can be monitored via three windows.
1. Home screen
   Battery bar and brief information can be read on home screen.
2. Battery detail information window
   Show smart battery data in real time and the data can be saved and printed in image format.
3.  Battery graph window
   Voltage, current and capacity are traced in curves.
Control
Battery Manager can control slave machine completely. Right-click menu on the battery bar includes the related commands.
Accessories
1).1 * adapter
2). 1 * USB cord
3). 1 * Disc
4). 14 * connectors
5). 10 * cables
6). 10 * jumpers
7). 1 * loader
Post Buying Request