Features
◆ Double circuit type of limit switch
◆ Highly rigid construction, consists of intensive plastic and aluminum cast (Head and cover snugly fit in box)
◆ Small volume, water-proof and oil-proof construction
◆ Built-in basic switch with double spring mechanism, longer mechanical life
◆ Smooth operation with greater OT
◆ Easy-to-wire circuit opening design
◆ Wide varity of actuators, easily use
|
Ratings
Rated Voltage |
Noninductive Load
(A)
|
Inductive Load
(A)
|
Resistance Load
|
Lamp Load
|
Inductive Load
|
Motor Load
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
125VAC
250VAC
500VAC
|
5
5
|
5
5
|
1.5
1
|
0.7
0.5
|
3
3
|
3
3
|
2
1.5
|
1
0.8
|
8VDC
14VDC
30VDC
125VDC
250VDC
|
5
5
5
0.4
0.2
|
5
5
5
0.4
0.2
|
3
3
3
|
3
3
3
|
5
4
4
|
4
4
4
|
3
3
3
|
3
3
3
|
Inrush Current
|
N.C: below 24A, N.O: below 12A
|
NOTES:
1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
2.Lamp load has an inrush current of 10 times the steady-state current,while motor load has
an inrush current of 6 times the steady-state current.
Characteristics
Operation speed |
0.5mm-50cm/sec
|
Operating frequency
|
Mechanical: 120 operations/minute, Electrical: 30 operations/minute
|
Contact resistance
|
25mΩ max. (initial value)
|
Insulation resistance
|
100mΩ min. (at 500VDC)
|
Dielectric strength
|
1000VAC, 50/60HZ for 1 minute between terminals of the same polarity
|
1500VAC, 50/60 HZ for 1 minute between currentcarrying
and non-current-carrying metal parts
|
1500VAC, 50/60 HZ for 1 minute between each terminal and ground
|
Vibration
|
10-55HZ,1.5mm double amplitude
|
Shock
|
Mechanical durable: 1, 000m/Sec2 (about 100G’S)
Malfunction: 300m/Sec2 (about 30G’S)
|
Ambient temperature
|
-5℃ to +65℃
|
Humidity
|
<95% RH
|
Life
|
Mechanical: 10,000,000 operations above
Electrical: 500,000 operations above
|
Weight
|
About 130 to 190g
|
Degree of protection
|
IP65
|
|