HFC Series Air Source Treatment
The HFC consisted of HFR andHL,each unit can be ordered separately.The HF with water separator cleans thecompressed air of fluid oil,condensation and dirt.Particles.For specialapplication,the standard 40 m filter element may easily be repla ced b y a 5µmfilter elementThe HR maintain imputting constant operating pressure despitefluctuation in line pressureand the amount of air consumed.The proportionallubricator adds a reg ulated qua ntity of o il to the filter ed air.
Theoil -mist content proportional to the flow and oil can be added duringoperation.The oil drip rate is controiled by the adjustable bolt.Normally,1to 12drops/1000L of the air is Suffcient.
HFC Service General technical data |
Size | Mini | Midi | Maxi |
Pneumatic connection | G1/8 | G1/4 | G3/8 | G1/4 | G3/8 | G1/2 | G3/4 | G1/2 | G3/4 | G1 |
Operating medium | Compressed air |
Design | Filter regulator with/without pressure gauge |
Proportional standard mistlubricator |
Typeof mounting | Via accessories |
In-line installation |
Assembly position | Vertical±5° |
Grade of filtration | [μm] | 5 or 40 |
Max. hysteresis | [bar] | 0.2 | 0.4 |
Pressureregulation range [bar] | 0.5 ... 7 |
0.5 ... 12 |
Pressure indication | Via pressure gauge |
G1/8 prepared | G1/4 prepared | G1/4 prepared |
Max. condensate volume | [cm3] | 22 | 43 | 80 |
Inputpressure | [bar] |
Condensate drain | turnedmanually | 1 …16 |
semi-automatic | 1.5… 16 |
fully automatic | 2 …12 |
Model | E1 | E2 | E3 | E4 | E5 | E6 | E7 | F1 | F2 |
HFC-MINI | 104 | 92 | 40 | 39 | 76 | 95 | 2 | G1/8,G1/4,G3/8 | M36x1.5 |
HFC-MIDI | 140 | 125 | 55 | 47 | 93 | 112 | 3 | G1/8,G1/2,G3/4 | M52x1.5 |
HFC-MAXI | 162,182 | 146,157 | 66 | 53 | 104 | 124 | 3 | G3/4,G1" | M36x1.5 |
Model | F3 | F4 | F5 | F6 | L1 | L2 | L3 | H1 | H2 | H3 | H4 | H5 | H6 |
HFC-MINI | 31 | M4 | 4.5 | 40 | 44 | 35 | 11 | 194 | 169 | 69 | 17.5 | 20 | 15 |
HFC-MIDI | 50 | M5 | 5.5 | 52 | 71 | 60 | 22 | 50 | 206 | 97 | 24.5 | 32 | 15 |
HFC-MAXI | 31 | M5 | 5.5 | 63 | 71 | 60 | 22 | 252 | 23 | 80 | 24.5 | 32,40 | 15 |
Service units HFC Standard flow rate qn as a function of the output pressure p2