Min. Order: | 1 PIECE |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, D/P, D/A, T/T, WU |
Supply Ability: | 10000 |
Place of Origin: | Zhejiang |
Location: | Hangzhou, Zhejiang, China (Mainland) |
---|---|
Business Type: | Trading Company, Agent, Distributor/Wholesaler, Service |
Main Products: | Mean Well Power Supply, LED Driver |
Model No.: | MDR-20-24 |
---|---|
Means of Transport: | Ocean, Air, Land |
Brand Name: | Mean Well |
Input Voltage: | 85 ~ 264VAC |
Output Voltage: | 24V |
Output Power: | 24W |
Output Frequency: | 50/60HZ |
Output Current: | 1A |
Production Capacity: | 10000 |
Packing: | 0.19Kg; 72pcs / 14.7Kg / 0.91CUFT |
Delivery Date: | 2 DAYS |
din rail switching power supply | MDR-20-24 | |
OUTPUT | DCVOLTAGE | 24V |
RATEDCURRENT | 1A | |
CURRENTRANGE | 0~1A | |
RATEDPOWER | 24W | |
RIPPLE & NOISE (max.) Note.2 | 150MVP-P | |
VOLTAGE ADJ. RANGE | 21.6 ~ 26.4V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | |
LINEREGULATION | ±1.0% | |
LOADREGULATION | ±1.0% | |
SETUP.RISEHOLD.TIME Note.5 | 500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 50ms/230VAC 20ms/115VAC at full load | |
INPUT | VOLTAGERANGE | 85 ~ 264VAC 120 ~ 370VDC |
FREQUENCYRANGE | 47~63HZ | |
EFFICIENCY (Typ.) | 84% | |
AC CURRENT (Typ.) | 0.55A/115VAC 0.35A/230VAC | |
INRUSH CURRENT (Typ.) | COLD START 20A/115VAC 40A/230VAC | |
LEAKAGE CURRENT | <1mA / 240VAC | |
PROTECTION | OVERLOAD | 105 ~ 160% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 27.6~ 32.4V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
FUNCTION | DC OK ACTIVE SIGNAL (max.) | 18~ 27V / 20mA |
ENVIRONMENT | WORKING TEMP | -20~+70 (refer to output load derating curve) |
WORKINGHUMIDITY | 20~90% RH non-condensing | |
STORAGE TEMP HUMIDITY | -40~+85 10~95%RH | |
TEMPCOEFFICIENT | ±0.03%(0~50) | |
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |
SAFETY&EMC Note 4) | SAFETY STANDARDS | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |
ISOLATIONRESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |
EMI CONDUCTICN& RADIATION | Compliance to EN55011, EN55022(CISPR22)classB | |
HARMONICCURRENT | Compliance to EN61000-3-2,-3 | |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A | |
QTHERS | MTBF | 236.9Khrs min MIL-HDBK-217F(25) |
DIMENSION | 22.5*90*100mm(L*W*H) | |
PACKING | 0.19Kg; 72pcs / 14.7Kg / 0.91CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. |