Switching Power Supply | NES-350-24 |
OUTPUT | DCVOLTAGE | 24V |
RATEDCURRENT | 14.6A |
CURRENtrANGE | 0~14.6A |
RATEDPOWER | 350.4W |
RIPPLE&NOISENOTE.2 | 150MVP-P |
VOLTAGEADJ.RANGE | 20 ~ 26.4V |
VOLTAGETOLERANCENOTE.3 | ±1% |
LINEREGULATION | ±0.5% |
LOADREGULATION | ±0.5% |
SETUP.RISEHOLD.TIME | 1000ms,30ms/230VAC ,1000ms, 30ms/115VAC at fill load |
INPUT | VOLTAGERANGE | 90~132VAC/180~264VAC by switch 254 ~ 370VDC |
FREQUENCYRANGE | 47~63HZ |
EFFICIENCY | 87% |
AC CURRENT | 7A/115VAC 4A/230VAC |
INRUSH CURRENT | 40A/115VAC 60A/230VAC |
LEAKAGECURRENT | <3.5mA / 240VAC |
PROTECTION | OVERLOAD | 105 ~ 135% rated output power |
Protection type Hiccup mode,recovers automatically after temperature N MJMNMgoes down |
OVER VOLTAGE | 27.6 ~ 32.4V |
Protection type Shut off |
OVER TEMPERATURE | 80 +/-5 (3.3~7.5V) 75 +/-5 (12~48V) (TSW1) Detect on case |
Proterction type:Shut down o/p voltage recovers automatically after temperature goes down |
ENVIRONMENT | WORKINGTIMP | -20~+60°C |
WORKINGHUMIDITY | -20~90%Rhnon-condensing |
STORAGE TEMP HUMIDITY | -20~+85°C 10~95%RH |
TEMPCOEFFICIENT | ±0.03%(0~45°C) |
VIBRATION | 10~500HZ,2G10min/1cycle period for 60 min each alongX,Y,Zaxes |
SAFETY&EMC | SAFETYSTANDARDS | UL60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATIONRESISTANCE | 1/P-0/P,1/P-FG,0/P-FG:100M Ohms/500VDC |
EMI CONDUCTICN& RADIATION | Design refer to EN55022 (CISPR22) Class A |
HARMONICCURRENT | Compliance to EN61000-3-2,-3 |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204,EN50204,EN61000-6-1 Light industry level criteriaA |
QTHERS | MTBF | 234.3K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 215*115*50mm (L*W*H) |
PACKING | 1.07Kg; 12pcs/13.5Kg/0.92CUFT |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |